RAW WATER CIRCUIT (open circuit)
Number of cylinders
16
Raw water pump: Inlet pressure, min.
L bar
-0.2
Raw water pump: Inlet pressure, max.
L bar
+0.5
Pressure loss in external raw water system, max.
L bar
1.0
LUBE OIL SYSTEM
Number of cylinders
16
Lube-oil operating temperature before engine, from
R °C
80
Lube oil operating temperature before engine, to
R °C
85
Lube oil operating pressure before engine, from
R bar
6.0
Lube oil operating pressure before engine, to
R bar
7.0
FUEL SYSTEM
Number of cylinders
16
Fuel pressure at engine supply connection, min. (when engine is starting)
L bar
-0.3
Fuel pressure at supply connection to engine, min. (when engine is run‐
ning)
L bar
-0.3
Fuel pressure at engine supply connection, max. (when engine is starting)
L bar
+0.5
Fuel supply flow, max.
R liter/min
4.2
GENERAL OPERATING DATA
Number of cylinders
16
Firing speed, from
R rpm
100
Firing speed, to
R rpm
120
STARTING (electric)
Number of cylinders
16
Starter, rated voltage (standard design)
R V=
24
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders
16
Starting air pressure before starter motor, min.
R bar
24*
Starting air pressure before starter motor, max.
R bar
30
68 | Product Summary | MS150031/03E 2011-10
TIM-ID: 0000011008 - 001
Summary of Contents for 12 V 2000 M40A
Page 4: ......
Page 20: ...Fuel system covers 20 Product Summary MS150031 03E 2011 10 TIM ID 0000002178 003 ...
Page 21: ...MS150031 03E 2011 10 Product Summary 21 TIM ID 0000002178 003 ...
Page 22: ...Lube oil system covers 22 Product Summary MS150031 03E 2011 10 TIM ID 0000002178 003 ...
Page 23: ...MS150031 03E 2011 10 Product Summary 23 TIM ID 0000002178 003 ...