3.12 8/10V 1600 G40F/G50F engine data, EU Nonroad Stage III A
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine
model
8V1600
G40F
8V1600
G50F
10V1600
G40F
10V1600
G50F
Application
group
3C
3C
3C
3C
Intake
air
temperature
°C
25
25
25
25
Barometric
pressure
mbar
1000
1000
1000
1000
Site
altitude
above
sea
level
m
100
100
100
100
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number
of
cylinders
8
8
10
10
Rated
engine
speed
A
rpm
1500
1500
1500
1500
Fuel
stop
power
ISO
3046
A
kW
394
394
448
493
GENERAL CONDITIONS (for maximum power)
Number
of
cylinders
8
8
10
10
Intake
depression
(new
filter)
A
mbar
25
25
25
25
Intake
depression,
max.
L
mbar
50
50
50
50
Exhaust
overpressure
A
mbar
85
85
85
85
Exhaust
overpressure,
max.
L
mbar
150
150
150
150
MODEL-RELATED DATA (basic design)
Number
of
cylinders
8
8
10
10
Standard housing connecting flange (en-
gine main PTO)
SAE
01
01
01
01
Flywheel
interface
DISC
14"
14"
14"
14"
AIR / EXHAUST
Number
of
cylinders
8
8
10
10
Charge-air pressure before cylinder - DL
R
bar abs
2.43
3.12
3.04
3.12
MS150076/05E 2014-02
| Technical Data | 59
T
I
M
-
I
D
:
0
0
0
0
0
2
0
1
9
3
-
0
0
2