8. Series M/MP heater technical specifications

(The indicated dimensions do not account for the outlet blower head and the burner) 

Weight 

kg

mm 

mm 

mm 

mm 

mm 

MP25 

1440 

530 

660 

1225 

150 

140

M25 

130

MP35 

148

M35 

130

MP50 

1650 

640 

870 

1390 

180 

210

M50 

138

MP65 

220

M65 

200

MP80 

1800 

750 

1000 

1525 

200 

315

M80 

210

MP100 

325

M100 

305

MP125 

2020 

800 

1230 

1760 

250 

480

M125 

450

MP150 

490

9. Sample nameplate on the back housing of the device.

Summary of Contents for MP25

Page 1: ...AIR HEATER UNIT TYPES M MP Original instruction manual v 08 2015 ...

Page 2: ...ssment of human responses to contact with surfaces Hot surfaces EN ISO 13857 2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs EN ISO 14159 2008 Safety of machinery Hygiene requirements for the design of machinery EN 60335 1 2002 A14 2010 Household and similar electrical appliances Safety General requirements EN 55014 1 2006 A1 2009 Electromag...

Page 3: ... it Failure to observe remarks indicated with this symbol may lead to damage to the heater or even to personal injury IMPORTANT This is an indication of the requirement to read the information found after it very carefully as this will contribute to safe use of the device 1 3 General indications Air heaters with heat exchangers may be used in rooms in which people remain WARNING Never install the ...

Page 4: ... casing is made of painted sheet steel and possesses a thermal insulation layer made of non flammable insulation wool with an aluminium layer Under the combustion chamber in the ventilation part there is the ventilator The ventilation chamber is protected by a mesh Furthermore the heater is equipped with the following safety devices ventilator thermostat automatically switches the ventilator on an...

Page 5: ...lator may turn on again this does not indicate of a flaw In order to shut down the entire heater set the main switch to position 0 4 3 LIMIT 2 safety thermostat When the air temperature exceeds 80 C the Limit thermostat shall shut down the burner and later it will turn it on again automatically If the thermostat does not operate properly and if the air temperature rises to 100 C the main safety th...

Page 6: ...vice safety thermostat MV fan TA room thermostat F1 fan fuse F2 burner fuse 400 V supply version IG main switch M fan TV FUN fan thermostat 35 C TLR contactor RT thermal relay BR burner TS overheat thermostat 110 C TSS burner shutdown thermostat 80 C TP room thermostat L coil FO fuse INT device function switch SR power supply diode STV fan failure diode STS overheat diode ...

Page 7: ...he burner A B C D E Weight kg mm mm mm mm mm MP25 1440 530 660 1225 150 140 M25 130 MP35 148 M35 130 MP50 1650 640 870 1390 180 210 M50 138 MP65 220 M65 200 MP80 1800 750 1000 1525 200 315 M80 210 MP100 325 M100 305 MP125 2020 800 1230 1760 250 480 M125 450 MP150 490 9 Sample nameplate on the back housing of the device ...

Page 8: ... 17 0 17 0 24 0 24 0 24 0 24 0 33 0 33 0 33 Volume m3 0 08 0 08 0 08 0 08 0 22 0 22 0 22 0 22 0 32 0 32 0 32 0 32 0 46 0 46 0 46 Mean exhaust gas temp C 195 195 228 228 196 196 229 229 196 196 228 228 229 229 241 Fuel cons l h 1 8 3 0 2 1 3 3 3 5 3 9 3 5 3 9 4 0 6 4 4 0 6 4 5 8 8 0 5 8 8 0 7 9 9 8 7 9 9 8 9 7 12 5 9 7 12 5 12 5 16 0 12 5 16 0 16 5 19 0 Air output m3 h 2170 2100 2860 2800 4100 4700...