The present instruction manual is an integral part of the device, and should always accompany it. 
Before start-up of the device, please read the Original Instruction Manual carefully, taking time to ensure full 
understanding: 
The manufacturer and retailer are not liable for the loss of health of persons or animals caused by: 
- usage of the equipment contrary to its foreseen use,
- usage of the equipment not in line with the original instruction manual,
- usage of the equipment contrary to fire and occupational safety provisions in force.

1. General rules

1.1. Foreseen use 

Type M and MP air heaters are foreseen for the heating and ventilation of rooms in which people remain or work. Type M 
heaters are equipped with axial ventilators, while type MP heaters are equipped with radial ventilators. 

1.2. Hazards stemming from improper heater use

 

The hot air chamber is equipped with safety devices that have been checked and tested. 
Improper use of the device can be hazardous to the persons making use of it, and possibly cause damage to components 
connected to the same electric circuit. 
Persons installing, using or servicing the heater should proceed in accordance with this Original Instruction Manual. 

Safety indications 

WARNING!

 

This is an indication of a potential hazard. Seeing this symbol, one should pay particular attention to information found 
below it. Failure to observe remarks indicated with this symbol may lead to damage to the heater or even to personal 
injury.

 

IMPORTANT!

 

This is an indication of the requirement to read the information found after it very carefully, as this will contribute to safe 
use of the device.

 

1.3. General indications

 

Air heaters with heat exchangers may be used in rooms, in which people remain.

 

WARNING!

 

Never install the heater in any room, in which there is any risk of explosions.

 

WARNING!

 

Exhaust fumes may cause a fire. Always maintain a safe distance to combustible materials.

 

1.4. Rules of safe operation 

The heater with a heat exchanger burns light fuel oil or diesel oil in a closed combustion chamber. The exhaust fumes are 
led to the outside through the chimney. Warm air is blown out by the ventilator. The ventilator is covered with a protective 
mesh on the air intake.

 

WARNING! 
Never use the heater without the ventilator safety mesh, as this may cause damage to persons and objects. 
IMPORTANT! 
The air intake and output openings must be uncovered at all times. 
WARNING! 
If the exhaust gases are directed straight towards any combustible material, this may cause a fire. 
WARNING! 
Before commencing any repairs or cleaning of the heater, remove the electric plug from the grid socket. Use the 
heater only as it is supposed to be used, meaning, solely and exclusively for heating and ventilation. 

1.5. Recommendations for the user 

The heater should be operated by a person who, before using the device, had thoroughly acquainted themselves with this 
Original Instruction Manual.

 

Summary of Contents for MP25

Page 1: ...AIR HEATER UNIT TYPES M MP Original instruction manual v 08 2015 ...

Page 2: ...ssment of human responses to contact with surfaces Hot surfaces EN ISO 13857 2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs EN ISO 14159 2008 Safety of machinery Hygiene requirements for the design of machinery EN 60335 1 2002 A14 2010 Household and similar electrical appliances Safety General requirements EN 55014 1 2006 A1 2009 Electromag...

Page 3: ... it Failure to observe remarks indicated with this symbol may lead to damage to the heater or even to personal injury IMPORTANT This is an indication of the requirement to read the information found after it very carefully as this will contribute to safe use of the device 1 3 General indications Air heaters with heat exchangers may be used in rooms in which people remain WARNING Never install the ...

Page 4: ... casing is made of painted sheet steel and possesses a thermal insulation layer made of non flammable insulation wool with an aluminium layer Under the combustion chamber in the ventilation part there is the ventilator The ventilation chamber is protected by a mesh Furthermore the heater is equipped with the following safety devices ventilator thermostat automatically switches the ventilator on an...

Page 5: ...lator may turn on again this does not indicate of a flaw In order to shut down the entire heater set the main switch to position 0 4 3 LIMIT 2 safety thermostat When the air temperature exceeds 80 C the Limit thermostat shall shut down the burner and later it will turn it on again automatically If the thermostat does not operate properly and if the air temperature rises to 100 C the main safety th...

Page 6: ...vice safety thermostat MV fan TA room thermostat F1 fan fuse F2 burner fuse 400 V supply version IG main switch M fan TV FUN fan thermostat 35 C TLR contactor RT thermal relay BR burner TS overheat thermostat 110 C TSS burner shutdown thermostat 80 C TP room thermostat L coil FO fuse INT device function switch SR power supply diode STV fan failure diode STS overheat diode ...

Page 7: ...he burner A B C D E Weight kg mm mm mm mm mm MP25 1440 530 660 1225 150 140 M25 130 MP35 148 M35 130 MP50 1650 640 870 1390 180 210 M50 138 MP65 220 M65 200 MP80 1800 750 1000 1525 200 315 M80 210 MP100 325 M100 305 MP125 2020 800 1230 1760 250 480 M125 450 MP150 490 9 Sample nameplate on the back housing of the device ...

Page 8: ... 17 0 17 0 24 0 24 0 24 0 24 0 33 0 33 0 33 Volume m3 0 08 0 08 0 08 0 08 0 22 0 22 0 22 0 22 0 32 0 32 0 32 0 32 0 46 0 46 0 46 Mean exhaust gas temp C 195 195 228 228 196 196 229 229 196 196 228 228 229 229 241 Fuel cons l h 1 8 3 0 2 1 3 3 3 5 3 9 3 5 3 9 4 0 6 4 4 0 6 4 5 8 8 0 5 8 8 0 7 9 9 8 7 9 9 8 9 7 12 5 9 7 12 5 12 5 16 0 12 5 16 0 16 5 19 0 Air output m3 h 2170 2100 2860 2800 4100 4700...

Reviews: