background image

 

 

830.1

 

STOVE STRUCTURE WITH FAN HOUSING 

830.2

 

- REAR COMBUSTION CHAMBER COVER 

830.3

 

- AXIAL FAN  fi250mm 

830.4

 

- FUEL TANK 

830.5

 

- FUEL TANK COVER 

830.6

 

- CONTROLLER HOUSING 

830.7

 

- CONTROLLER LABEL 

830.8

 

- OVERFLOW PROTECTION 

830.9

 

- CAPILLARY HANDLE 

830.10

 

- ELECTRONIC PLATE OF THE CONTROLLER 

830.11

 

- FUEL PUMP BRACKET 

830.12

 

- DRIVE SHAFT OF THE FUEL PUMP 

830.13

 

- FEEDING TUBE FOR THE COMBUSTION CHAMBER 

830.14

 

- MTM 8-30 STOVE SWITCH 

830.15

 

- FUSE SOCKET 

830.16

 

- RUBBER GLAND 

830.17

 

- ELECTRONIC PLATE TRANSFORMER OF THE MTM 8-30 STOVE 

830.18

 

- CAPILLARY CONTROL THERMOSTAT 

830.19

 

- FUEL DUCT T-PIPE 

830.20

 

- COMBUSTION CHAMBER 

830.21

 

FUEL PUMP FILTER 

830.22

 

- CLEANING BLADE FOR THE COMBUSTION CHAMBER 

830.23

 

- STB THERMOSTAT 

830.24

 

- OVERFLOW MICROSWITCH 

830.25

 

- CAST IRON FURNACE PAN 

830.26

 

- CAST IRON COMBUSTION CHAMBER DEFLECTOR 

830.27

 

- COMBUSTION CHAMBER CYLINDER 

830.28

 

- COMBUSTION CHAMBER RING 

830.29

 

- FUEL PUMP 

830.30

 

- RUBBER FEEDING FUEL DUCT 12 cm LONG 

830.31

 

- RUBBER OVERFLOW FUEL DUCT 30 cm LONG 

830.33

 

- FUEL PUMP MOTOR 

830.34

 

- SUPPLY CABLE 230 WITH A PLUG 

830.35

 

- ELECTRIC FIRE-RESISTANT WIRE 3X 105 cm LONG STB 

830.36

 

- ELECTRIC FIRE-RESISTANT WIRE 3X 115 cm LONG FAN 

830.37

 

- ELECTRIC FIRE-RESISTANT WIRE 3X 145 cm LONG OVERFLOW PAN 

830.38

 

- LARGE GLAND 

830.39

 

- COMBUSTION CHAMBER COVER 

 

 

List of servicing parts for MTM 8-30 

Summary of Contents for 8-30

Page 1: ...UNIVERSAL OIL HEATER TYP MTM 8 30 kW V 08 2015 ORIGINAL MANUAL ...

Page 2: ...vironment Methods for the assessment of human responses to contact with surfaces Part 1 Hot surfaces EN ISO 13857 2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs EN ISO 14159 2008 Safety of machinery Hygiene requirements for the design of machinery EN 60335 1 2002 A14 2010 Household and similar electrical appliances Safety Part 1 General req...

Page 3: ...ON THE REAR ENCLOSURE OF THE DEVICE 2 Storage environmental conditions The universal oil heater type MTM 8 30 must be stored in the following conditions temperature 20 85 C relative humidity 5 85 pressure 800 1200 hPa no dusting environment free from chemical contamination 3 Use environmental conditions The universal oil heater type MTM 8 30 must be used in the following conditions temperature 0 3...

Page 4: ...nts sensors pump fan is factory made During normal use due to operation safety under no circumstances should there be any interference in the covered and sealed part of the stove controller or duct integrity Any action by an unauthorised person may result in electrocution 230V AC 50Hz and burning 6 Structure of STOVE MTM 8 30 Fig 1 MTM 8 30 heater structure Fig 2 MTM 8 30 heater block diagram BIME...

Page 5: ... the following indications have to be followed diameter of the exhaust fumes outlet from the device is 130 mm recommended diameter of the stack pipe is 130 150 mm minimal stack height with diameter of 150 mm is 5 metres check the tightness of the stack component connections wind should freely fan the stack outlet from all directions the end of the stack pipe should be above the rooftop level wind ...

Page 6: ...bly by ca 1 m The places where the stack penetrates the ceiling walls or roof must be insulated in order to avoid fire hazard It is recommended to use a double layered insulated stack pipe wherever contact is possible as well as outside the building in order to ensure continuous draught and prevent condensation Do not place any materials near the stove even non flammable ones Provide continuous ai...

Page 7: ...ch 0 1 is turned on Due to decreased oil demand by a non heated furnace after the start up of the device it should operate with 19 kW power for at least 15 minutes After ca 15 minutes of operation when the furnace pan is sufficiently heated up and is able to evaporate a greater amount of oil the power of the device can be switched to 30 kW or lower 8 kW During maximum power operation the amount of...

Page 8: ...NS 9a Starting the device if needed remove water from the fuel tank and fill it with oil e g used oil check whether the overflow protection mechanism works properly by pushing the bowl lever down and letting it come back to its original position which will be confirmed by the characteristic click sound check whether the device burner is maximally pushed to the housing of the device if not push unt...

Page 9: ...e great temperature difference can break and will be unfit for use 9c Maintenance The heater does not require many maintenance procedures Observance of the manufacturer s recommendations in this scope will ensure failure free and safe operation of the device clean the furnace pan every day as well as other elements of the combustion chamber cylinder deflector and cover check patency of the overflo...

Page 10: ...ntrol thermostat and replace it if needed Check the motor and see if the pump is not soiled on the inside Check STB and overflow protection 5 The fuel ducts is obstructed oil returns to the tank through the primary duct Clean the fuel duct and replace it 6 The pump operation control thermostat has not reached proper temperature Wait until the furnace cools down and restart it Replace the thermosta...

Page 11: ...Servicing part diagram for MTM 8 30 ...

Page 12: ...STAT 830 19 FUEL DUCT T PIPE 830 20 COMBUSTION CHAMBER 830 21 FUEL PUMP FILTER 830 22 CLEANING BLADE FOR THE COMBUSTION CHAMBER 830 23 STB THERMOSTAT 830 24 OVERFLOW MICROSWITCH 830 25 CAST IRON FURNACE PAN 830 26 CAST IRON COMBUSTION CHAMBER DEFLECTOR 830 27 COMBUSTION CHAMBER CYLINDER 830 28 COMBUSTION CHAMBER RING 830 29 FUEL PUMP 830 30 RUBBER FEEDING FUEL DUCT 12 cm LONG 830 31 RUBBER OVERFLO...