emergency mode, cutting off inflow of fuel, thus securing the fan against overheating or melting
of its elements.
3. Microswitch - weight sensor located under the combustion chamber. Filling the pan causes
immediate switching into the emergency mode, cutting off the fuel inflow, securing against
leakage of the excess non-evaporated fuel outside the combustion chamber, eliminating the possibility of its
ignition
outside the device.
The connection of the stove controlling panel to other system components (sensors, pump, fan)
is factory-made. During normal use, due to operation safety, under no circumstances should there be any
interference in the covered and sealed part of the stove controller or duct integrity. Any action by an
unauthorised person may result in electrocution (230V AC, 50Hz) and burning.
6. Structure of STOVE MTM 8-30
Fig. 1. MTM 8-30 heater structure
Fig. 2. MTM 8-30 heater block diagram.
BIMETALLIC
OVERHEAT
SENSOR (STB)
RESET
CONTROLLER
FUEL
TANK
FUEL
FEEDING
PUMP
BURNER
CONTROL
THERMOSTAT
FAN
HOUSING
UPPER
HOUSING
OF THE
COMBUSTION
CHAMBER
EXHAUST FUMES OUTLET
COMBUSTION
CHAMBER
TROLLEY
OVERFLOW
SENSOR
CONTROL
THERMOSTAT
FAN
CONTROLLER
FUEL
PUMP
MOTOR
OVERFLOW
PAN
TR
A
N
S
FOR
ME
R
FU
S
E