27

MTH GP60M Diesel Operating Manual

PREMIER

LINE

Periodically, check the locomotive wheels and pickups for dirt buildup as

this can significantly affect the engine’s ability to perform properly. Dirty
track and dirty wheels can cause both poor electrical contact as well as poor
traction, especially on elevated track sections. Finally, dirt and oil build up
can prematurely wear out the neoprene traction tires.

TRACTION TIRE REPLACEMENT
INSTRUCTIONS

Your locomotive is equipped with two neoprene rubber traction tires on

the middle axle of each drive truck. While these tires are extremely durable
and long-lasting there may arise a time where they will need to be replaced.
Should this occur, you will need to remove the trucks from the chassis and
the trucksides from the trucks in order to slip the new tire over the grooved
drive wheel. Figures 7 and 8 identify the screws necessary to remove the
body and trucks from the chassis.

Before the new tire can be installed, you must make sure the old tire has

been completely removed from the groove in the drive wheel. Use a razor
blade or small flatblade screwdriver pry away any remains left from the old

tire that may still be in the drive wheel groove.

Once the old tire has been

completely removed, slip the new tire onto the wheel. You may find it
useful to use two small flatblade screwdrivers to assist you in stretching the
tire over the wheel. Be careful to avoid twisting the tire when stretching it
over the wheel. If a twist occurs, the tire will have to be removed and
reinstalled or a noticeable wobble in your engine will occur when operating
the locomotive. In addition, it is important to make sure that the tire is

Cab To Chassis

Mounting Screw

Cab To Chassis

Mounting Screw

Cab To Chassis

Mounting Screw

Figure 8: Removing The Body From The Chassis

Summary of Contents for PREMIER GP60M

Page 1: ...g instructions and is completely compatible with most other 3 rail locomotives rolling stock and accessories The locomotive is equipped with several deluxe features that are simple and fun to operate...

Page 2: ...T Options 18 Setting The Engine Volume 19 Programming For A Separate Bell Button Controller 20 Programming For Squeaking Brake Operation 20 Programming For Horn In Neutral Operation 21 Programming For...

Page 3: ...f so equipped The reverse unit is designed to ignore dirty track dead spots on switches or minor short circuits without disrupting the engine operation even at slow prototypical speeds Once the engine...

Page 4: ...lied to the track the reverse unit begins in RESET or what seems like a neutral state Power must be interrupted again to get the locomotive to enter the forward state It is this first RESET state that...

Page 5: ...your locomotive using any of these programmable features simply leave RESET and wait 2 2 seconds before interrupting the power to put the engine in forward After you leave RESET your engine will oper...

Page 6: ...rottle to 8 volts or less any higher voltage will arm the ProtoCoupler and press the whistle button The bell should begin chiming To turn the bell off press the whistle button again If you want to kee...

Page 7: ...r rear coupler Simply slide the switch toward the direction of the coupler you want to make active NEUTRAL ACTIVATED CAB CHATTER SOUNDS Your engine is equipped with four dispatacher to engineer Cab Ch...

Page 8: ...our engine may continue to play the brake sounds once your engine comes to a stop or that the sounds stop prematurely before the engine comes to a complete halt For example if you simply run the engin...

Page 9: ...ture of a freight train in a freight yard Each sequence is described in more detail in the following sections USING FREIGHT YARD SOUNDS Your ProtoSound equipped engine features an operator controlled...

Page 10: ...turn on the transformer throttle and get your engine into the Neutral position not RESET Once in Neutral set the transformer throttle at 8 volts or less and press and hold the whistle button for at le...

Page 11: ...ntrolled events control FYS s actions and sound effects Event 1 Forward While the locomotive is running in forward or reverse FYS is activated by the operator pushing and holding the bell button down...

Page 12: ...se FYS confirms to the operator that it has entered the reverse phase by immediately playing a highlight sound best described as a rumbling sound You may have to go through the entire FYS sequence sev...

Page 13: ...t the throttle setting too high or the engine will go racing away faster than you might expect TIPS ON USING FYS FEATURES FYS is a unique feature of ProtoSounds that is completely controlled by the op...

Page 14: ...d operations To disable FYS see the section on programming for squeaking brakes and FYS operation on page 23 of this manual Tip 5 It is not necessary for the squeaking brake sounds to be heard to play...

Page 15: ...e the cab body is a special NiCad 7 cell 8 4v battery NOT the 6 cell 7 2v battery found in most convenience stores The 6 cell NiCad is NOT recommended for use with ProtoSound applications The battery...

Page 16: ...f the chassis See Fig 4 below allows you to control all the sounds in the system and a remote control RESET option Option 6 allows you to control the volume level of the engine sounds remotely from th...

Page 17: ...ce one feature at a time through the available options An air release sound is heard each time the throttle is advanced In addition there are special sounds to tell you what RESET position you are in...

Page 18: ...ve you 50 volume pushing it a third time will give you 25 volume and pushing it a fourth time will give you no sound The microprocessor will immediately play the sound level each time the whistle butt...

Page 19: ...ings signifying that the module has been programmed for a bell button Simply turn the throttle off and then on again to Lock In the new setting To reset the computer to its original factory default se...

Page 20: ...ocedure but keep pushing the whistle button until the module only responds with two bell dings PROGRAMMING FOR HORN IN NEUTRAL OPERATION If you are operating your engine with a separate bell button an...

Page 21: ...or triple heading ProtoSound equipped engines since every engine equipped with a ProtoCoupler will fire when prompted to by the operator By turning off the ProtoCoupler operation on certain engines yo...

Page 22: ...track sections The lockout feature comes from the factory in the OFF position meaning it is not active when you first take the engine out of the box This is done to prevent novice operators from acci...

Page 23: ...e to enter forward TURNING OFF CAB CHATTER SOUNDS Cab Chatter sounds occur in the neutral position every 2 to 30 seconds There are four Chatter messages which play at random times This helps to elimin...

Page 24: ...OFF AND THEN LET GO OF THE WHISTLE BUTTON After about one second you will hear a short horn blast QUICKLY TURN THE THROTTLE BACK ON AGAIN Your engine is now locked into Forward or Reverse and it will...

Page 25: ...or coupler firing depending on the transformer throttle voltage settings prior to the user s attempt to lock out the engine Remember the whistle doesn t blow in NEUTRAL unless you programmed it to do...

Page 26: ...factory and shouldn t need additional grease until after 50 hours of operation or one year whichever comes first Grease can be added by inserting grease into the gear box inside the locomotive chassi...

Page 27: ...tire over the grooved drive wheel Figures 7 and 8 identify the screws necessary to remove the body and trucks from the chassis Before the new tire can be installed you must make sure the old tire has...

Page 28: ...ic Trains HEADLIGHT REPLACEMENT The locomotive s headlights are controlled by constant voltage circuits inside the locomotive body The headlight s can be easily removed from its lampholder should the...

Page 29: ...on is depressed fully the ProtoSound circuit may not recognize the signal Try pressing the whistle button slower taking approximately 1 second to fully depress the button BELL PROBLEMS REMEDY When I p...

Page 30: ...up the transformer It sits still with the diesel compressor sounds running The engine is locked out into the Neutral position Follow the unlocking proceedures in the Lockout Section The engine won t...

Page 31: ...diesel startup sounds have completed This will guarantee that the system check will have been completed since the startup sounds take longer than 2 2 seconds to play If the problem persists we recomme...

Page 32: ...urn on the bell when the system enters Event 5 After approximately 15 rings of the bell it automatically will turn off Whenever FYS is enabled pressing the whistle and bell buttons has no affect Becau...

Page 33: ...90 Watt Standard Lionel 1043 U A 5 16v 90 Watt Standard Lionel 1043M U A 5 16v 90 Watt Standard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 W...

Page 34: ...be followed including the following Read this and all related manuals transformer power supply locomotive etc thoroughly before using this device This device is not recommended for children under ten...

Page 35: ...ion number a copy of your sales receipt and a full description of the problem must be included to facilitate the repairs Please include the description regardless of whether you discussed the problem...

Reviews: