MTG
- 46 -
MPC Keypad v4.00
Get/Set Global Parameter List
The following table describes the address and data elements that are valid for
the Get/Set Global Parameter commands.
Parameter #
(hex)
Combined Byte
Value
(binary)
Description
08
0000 nnnn
n = MIDI Channel for manual mode
0 to 15 (for MIDI channels 1 to 16)
09
0000 000x
x = Program Change number range
0 is 0-127
1 is 1-128
0A
0000 000x
x = Bank Select number range
0 is 0-127
1 is 1-128
0C
0ddd dddd
d = Sys Ex Mfg ID (default is 7D)
01 to 7D (7E and 7F are reserved)
0D
0000 000b
Keypad beeper enable.
0E
0000 000m
m = 0 = Preset Mode NORMAL
m = 1 = Preset Mode BROWSE
0F
0000n nnnn
0 = Do not receive program change.
1-16 = Rx Pgm Chg on ch 1 to 16.
17 = Rx Pgm Chg on ALL channels.
10 to 19
pppp pppp
Preset number assigned to Speed Dial
(0 to 199 decimal corresponds to
Presets 1 through 200).
1A
0000 000m
m = 0 = MIDI Pass-Thru OFF
m = 1= MIDI Pass-Thru ON
7
Crossed out commands are not recommended. Using other parameter numbers is undefined.
Program Change Range works in v2.79 and then v3.30+, not in between
7
MIDI Pass-Thru should always be OFF when configuring the keypad over MIDI! Attempting to
communicate with the keypad over MIDI while it is ON will be fruitless!