3.2.
Preparations for operation
POSITIONING THE APPLIANCE
Operate this product in locations where good air circulation is ensured and away
from sources of electromagnetic radiation, fire, and flammables. The ambient
temperature shall be b5°C and +40°C. The operating location of the
appliance shall provide immediate access to the stop valve of the compressed air
supply and to the power cord plug. The compressed air supply pressure of the
appliance shall not exceed the specified range.
APPLIANCE AIR FLOW LIMITS
AIR FLOW RATE SPECIFICATIONS
TOTAL AIR
FLOW RATE
[Nm
3
/h]
FLUIDISED POWDER
RATIO TO AIR
[%]
INJECTOR PUMP
DISCHARGE
(TRANSPORT)
AIR [Nm
3
/h]
MAKE-UP AIR
[Nm
3
/h]
6.5
81
5.4
1.1
40
3.7
2.7
0
1.8
4.6
5.5 [Nm
3
/h]
100
5.4
0
50
3.6
1.8
0
1.8
3.6
4.0 [Nm
3
/h]
100
4.0
0
50
2.8
1.2
0
1.8
2.2
The total air flow rate is the transport air plus the make-up air for the powder ratio
(expressed as a percentage). The total air flow rate is thus kept steady.
The specified air flow values are indicative only. Appliance tear and wear, ambient
conditions, and the type of used powder may affect the actual air flow rate.
INSTALLING THE APPLIANCE
Summary of Contents for MSW-PCSM-100-1
Page 31: ...ASSEMBLING THE CONTROL UNIT COMPONENTS INSTALLING THE REINFORCED HOSES LINES BACK PANEL ...
Page 49: ...MONTAŻ ELEMENTÓW JEDNOSTKI STERUJĄCEJ INSTALACJA WĘŻY ZBROJONYCH PRZEWODÓW PANEL TYLNI ...
Page 68: ...MONTÁŽ PRVKŮ ŘÍDICÍ JEDNOTKY INSTALACE HADIC VODIČŮ ZADNÍ PANEL ...
Page 76: ......
Page 144: ...VEZÉRLŐEGYSÉG ELEMEINEK ÖSSZESZERELÉSE MEGERŐSÍTETT TÖMLŐ VEZETÉK TELEPÍTÉSE HÁTSÓ PANEL ...
Page 152: ......
Page 162: ...MONTERING AF STYREENHEDENS KOMPONENTER MONTERING AF SLANGER LEDNINGER BAGPANEL ...
Page 170: ......