background image

User’s  Manual

                                                                               

        PSE-SW5G2280HM

 

 

 
MSTRONIC CO., LTD.                                                         

                                                                   

   

 

8

  PSE disconnect mode      DC disconnect 
 
  PoE auto detection 

  IEEE802.3af & IEEE802.3at (2 event classification signaling) 

 
  PoE protection 

 

  Over-temperature, over-current, over/under voltage 

 

LEDs                                  *Link/Activity (Green ON/ Green Blinking @1000Mbps,       

Yellow/Yellow Blinking @10M/100Mbps)           

                                            *PoE (Yellow): port 1-3 ON - PD detect,                                                                                   

port 4-5 ON – 24V output 

 

 

                            *POWER: Green-normal, Red-24V passive PSE alarm   

 
  Power input                      18V~32VDC input @ rear terminal 
 
  Power consumption          <5W without PD loading 
 
  Power efficiency              85% at full load (@24V typical) 
 
  Operating temperature      -40

~ +70

℃ 

 

 

  Operation humidity          90% relative humidity, non-condensing with conformal coating 
 
  Storage temperature       

-40

~+85

℃ 

 

  Dimension                      40mm(H)x180mm(W)x150mm(D)    DIN rail mount available 
   

 

Summary of Contents for PSE-SW5G2280HM

Page 1: ...USER S MANUAL MSTRONIC CO LTD PSE SW5G2280HM 5 Port PoE Switch Combo 56V 24V...

Page 2: ...ough the traditional UTP or STP cable 2 Hardware Description LED Indicator There are 12 LEDs on the PoE switch to indicate the status of power and signal The following section describes the functions...

Page 3: ...package from another device at 10Mbps or 100Mbps Off No device is detected PoE LED the left indicator on RJ45 P1 P3 802 3at PoE Yellow A valid Powered Device PD is detected and delivering power on th...

Page 4: ...below Data pair A plus V on line 1 and 2 Data pair B plus V on line 3 and 6 Data pair C plus V on line 4 and 5 Data pair D plus V on line 7 and 8 The terminal block on rear panel should be wiring as M...

Page 5: ...irs The following tables describe the wiring diagram of straight through and crossover cabling That crossover cables simply cross connect the transmit lines at each end to the receive lines at the opp...

Page 6: ...gnment The following table shows pin assignment of alternative A and B for the Power Source Equipment Conductor Alternative A MDI X Alternative A MDI Alternative B All 1 Negative Vport Positive Vport...

Page 7: ...ull duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T 14880pps for 10base T Address table 1K MAC address table self learning Connect RJ 45 PoE po...

Page 8: ...1000Mbps Yellow Yellow Blinking 10M 100Mbps PoE Yellow port 1 3 ON PD detect port 4 5 ON 24V output POWER Green normal Red 24V passive PSE alarm Power input 18V 32VDC input rear terminal Power consump...