FILTRATION

Press the           

FILTER

 button to turn the function on/off. The light turns to green when the function is activated.

NOTE:

 The filtration system will automatically start when the heating, Ozone or UVC sanitizing system is activated.

NOTE:

 After turning off the heating system, the filtration system will automatically stop in 30 seconds. 

Filter Cartridge Cleaning Reminder:

 When the FILTER button is flashing or displays red, the filter cartridge must be cleaned or replaced. Once 

this has been done, press the Filter button for 3 seconds to reset the reminder.

Auto-filtration:

 When the spa is in stand-by mode, the filtration system will operate automatically for 60 minutes every 8 hours.

BUBBLE MASSAGE 

Press the           

BUBBLE

 button to turn the function on; hold down the BUBBLE button for 3 seconds to turn the function off. The BUBBLE button 

displays green when activated. 
The bubble setting can be adjusted to three different levels. The default setting is at level 2 (500W). Press the 

BUBBLE 

button to switch the 

setting to level 3 (720W). Press it again to switch to level 1 (300W). 

IMPORTANT:

 Do not turn on the massage system when the cover is attached. Air can accumulate inside the spa and cause irreparable damage 

and bodily harm.

NOTE:

 The bubbling massage function will shut down automatically after every 20 minutes of operation as a safety precaution. This can be 

reactivated after 10 minutes by pressing the BUBBLE button again.

HEATING TIMER

To set the number of hours 

FROM NOW

 when the heater will activate:

1.  Press the           

TIMER

 button to enter pre-setting mode. The button displays green.

2.  Pressing the         

UP 

or         

DOWN

 button will cause the LED to flash. While it is flashing, you can adjust the number of hours before heater 

     activation (from 1 to 99 hours). The desired timer setting will remain on the LED display for 3 seconds to confirm the value.

To modify the timer setting: 

Press the 

Timer

 button again and use the 

UP

 or the 

DOWN

 button to adjust.

Cancel the setting:

 Press the 

TIMER

 button for 3 seconds.

NOTE: 

Activating the heating system or rebooting the spa will cancel the timer setting.

UVC SANITIZER

Press the           

UVC

 button to turn the UVC sanitizing system on/off. When the light above this button is green, the UVC sanitizing system is 

activated.

NOTE:

 The UVC emitter is built inside the control box. Therefore, the function can be turned on at any time, even with people inside the spa. 

OZONE

Press the           

OZONE

 button to turn the function on/off. The OZONE button displays green when the function is activated. The Ozonator will 

shut down automatically after operating for 2 hours. 

NOTE: 

For your own safety, do not bathe in the spa when the OZONE function is turned on. The OZONE function cannot be turned on when the 

JET or BUBBLE function is on. We suggest turning on the function after using the spa.

Celsius/Fahrenheit Toggle Button

The temperature can be displayed in either Celsius or  Fahrenheit. Press the           

DOWN

 button for 3 seconds to toggle between the two 

options.

SAFETY LOCK

 

Press the         

UP

 and         

DOWN

 buttons at the same time for 3 seconds to lock/unlock the controller. In safety lock mode, the controller is 

disabled and the spa retains all previous settings. 

BUBBLE

TIMER

12

UP

DOWN

UP

DOWN

DOWN

1-99H

TIMER

BUBBLE

3s

UP

DOWN

3s

DOWN

+

FILTER

FILTER

Summary of Contents for Carlton M-CA062

Page 1: ...change the specifications and appearance of its products which may result in updates to the instruction manual without prior notice M CA062 Carlton M OT062 Otium PLEASE DO NOT RETURN THE PRODUCT TO T...

Page 2: ...MSpa Welcome CONTENT Safety precautions Specifications Product overview First use and set up preparation Spa set up Controller operation Water maintenance and chemicals Drainage cleaning and storage P...

Page 3: ...ugs to connect the unit to the electrical supply provide a properly located outlet This appliance with its incorporated heating elements must be connected to a grounded mains supply socket with a supp...

Page 4: ...ian before using a spa h Persons using medication should consult a physician before using a spa since some medication may induce drowsiness or affect the heart rate blood pressure or circulation i Che...

Page 5: ...spa is not in use store it away immediately or keep it in an enclosed area Open the spa top lid when the Bubble function is on In order to avoid a hazard due to the inadvertent resetting of the therma...

Page 6: ...and fixed partitions Zones Zone 0 Zone 1 Zone 2 Description of the zones Zone 0 is the interior of the basin including any recesses in the walls or floor Zone 1 is limited by Zone 0 A vertical plane 2...

Page 7: ...terial AC 220 240V 50Hz 2300W 2200W 3 Levels Level 1 300W Level 2 500W Level 3 720W 1800L h 5 5W 30 50mg h 220 240V 225W 75W x 3 sets 6 high efficiency hydro jets 2000uW Rhino Tech reinforced PVC PVC...

Page 8: ...vide an adequate drainage system around the spa to deal with overflow water and splashes Provider a convenient water supply for filling the spa that complies with any local water regulations and whose...

Page 9: ...und cloth with the bubbles facing down over the cleared area where you intend to set up your spa 1 Press the UP button and the BUBBLE button at the same time to start auto inflation 2 The inflation wi...

Page 10: ...tub with fresh water to a level between MIN and MAX marked on the inside of the spa wall 1 Open the air valve c on the spa pool Ensure that you select the black one Open the air valve a on the bladde...

Page 11: ...is activated When the light is green the water is at the set temperature and the heating system is at rest 2 Pressing the UP or DOWN button will cause the LED to flash When it is flashing you can adj...

Page 12: ...R button to enter pre setting mode The button displays green 2 Pressing the UP or DOWN button will cause the LED to flash While it is flashing you can adjust the number of hours before heater activati...

Page 13: ...the buckle cover to prevent pollution 4 Use spa chemicals to maintain the proper water conditions Spa damage resulting from the misuse of chemicals or the mismanagement of spa water is not covered by...

Page 14: ...before refilling with clean water IMPORTANT Do not use steel wool hard brushes or abrasive cleaners Deflation Instructions Spa deflation 1 Unscrew the valve completely to deflate the spa 2 Once defla...

Page 15: ...The manometer should always point to the Green section when spa is filled with water When leaving the spa outdoors unattended for long periods of time release some air until the manometer points to th...

Page 16: ...ove do not turn on the bubble function This is because the rain in the air is also sucked into the pump causing the bubble generator to get damp and rusty which could result in malfunction and void yo...

Page 17: ...ated the leak clean and dry the leaking area then use the repair patch supplied with your spa Check the repair section on P15 Change the water Extend the filtration time Clean or replace the filter ca...

Page 18: ...ing flood or other external causes This warranty is valid only in the country of purchase in such countries where MSpa sells and services the same model with identical technical specifications Warrant...

Reviews: