Page 8
MSI-4300 Porta-Weigh Plus/7 Key
•
User Guide
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
2.
SHIFT ZERO/SETUP: Enables the setup menus. Controls for
Units, Filtering, Backlight, Set Points, IR Remote, Auto
Power (off), and Total mode are found in the Setup menu.
(Legal-for-trade units may have a subset of these functions).
3.
SHIFT NETGROSS/PEAKHOLD: Enables/disables the
Peak-Hold function. The highest reading is captured. Use
Shift-Clear to erase the current peak.
4.
SHIFT TARE/TARE MEMORY: Enables the Tare Memory
menus. Use the Select and Enter yes to store and/or apply up
to 9 tare values.
5.
SHIFT TOTAL/CLEAR: Used to Erase (Clear) Peak-Hold
values and numeric values. The Clear function is also a
useful shortcut out of various setup menus.
6.
SHIFT VIEW
∑
/SELECT: The select key is used to scroll
through various menu choices in Setup, Tare and Calibration
menus. It is also used to input numbers for Setpoints, Tares
and Calibration.
7.
SHIFT: Used in conjunction with the Select key to enter
selected values or parameters. This function of the Shift key
is only active when it is needed.
OPERATION GUIDE
POWER
METRIC
AUTO
REMOTE
∑
0
MOTION
+
-
Function:
Turns the Scale On/Off (toggle action).
Use:
1)
The batteries must have enough charge to ensure accurate
operation. (8 batteries in series must total more than 5.4V).
2)
Ambient temperature must be greater than -30
°
C and less
than 60
°
C (-22
°
to 140
°
F).
Action:
1)
Push POWER button.