38 MSI-8000HD Operator’s Manual
Auto Total does
not work
Load must be stable
Wait for stable symbol
to turn on
or increase filtering for more stability
Load thresholds not
reached
You must exceed 1% of capacity for
autototal to work. Then you must drop
below 0.5% of capacity for additional
weighments to register.
Charger RED light
is on
Battery deep
discharged
Disconnect charger, reconnect. If still red,
charge for 24 hours to see if it recovers.
Disconnect the charger. Open the case
and disconnect the cord from the internal
charger board to the display board.
Charge for 24 hours. If the charger LED is
still RED, the battery will need
replacement. This procedure is only
recommended for experienced
technicians.
Ambient temperature
is too high
The battery charger won’t fast charge in
high ambient temperatures. Place the
system in a cooler environment.
Ambient temperature
is too low (<-20°C,
14°F)
The battery charger won’t fast charge in
low ambient temperatures. Place the
system in a warmer environment
Charger LED
remains blue and
never turns green
The
MSI-8000HD
is
on.
Turn off the
MSI-8000HD
. While power is
being drawn fromt the battery, it won’t top
off the battery.
The battery condition
is poor.
Replace the Battery.
Problem
Possible Cause
Solution
Table 6-1. Troubleshooting