26 MSI-8000HD Operator’s Manual
5.7 Control Modes
The user can select four control modes:
•
User
- Printing is controlled by the operator pushing the PRINT key (usually F3).
•
Load
- One print occurs when a stable load is reached. The scale must then return
to near zero before another print will occur. Other configurations of “On Load”
are available using the ScCMP application (ScaleCore Configuration
Management Program).
•
Continuous
- The
MSI-8000HD
will continuously output the data at a rate
controlled by the “rAtE” (RATE) menu.
•
Off
- Printing is disabled. Power consumption is lower with print off.
5.8 Standard Print Strings
Figure 5-6. Standard Print Strings
1
Current load
Fixed output length: 16. Leading zeros suppressed except for the
LSD.
TTTTTTT
sp
UU
sp
MMMMM
crlf
Where
TTTTTTT
is load data with -sign if necessary.
UU
is the
units,
MMMMM
is the load mode which for “1” is either NET or
GROSS
2
Net load
Fixed output length:16. Leading zeros suppressed except for the
LSD.
TTTTTTT
sp
UU
sp
NET
spspcrlf
3
Gross load
Fixed output length: 16. Leading zeros suppressed except for the
LSD.
TTTTTTT
sp
UU
sp
GROSS
crlf
4
Tare Weight
Fixed output length:16. Leading zeros suppressed except for the
LSD.
TTTTTTT
sp
UU
sp
TARE
crlf
5
Total
Weight
Fixed output length: 16. Leading zeros suppressed except for the
LSD.
TTTTTTTTT
sp
UU
sp
TTL
crlf
6
Number of
Samples
Totaled
Fixed output length: 16. Leading zeros suppressed except for the
LSD.
spspspspspsp
SSSSSSS
sp
T-CNT
spcrlf
7
Current
Weight
Mode
Net, Gross, Peak, etc
sp
MMMMM
crlf
8/9
Carriage
Return/
Line Feed.
Used to add a space between print records.
crlf
In the string number entry screen, you can enter combinations of the standard print
strings. For example, to get a NET GROSS TARE printout with a space between
records, simply enter “2349.”