1.

 

DESCRIPTION 

 .........................................................................................................................................................

3

2. TECHNICAL CHARACTERISTICS

 ..........................................................................................................................

4

3. CONTROL UNITS

 ....................................................................................................................................................

5

    3.1  Buttons .............................................................................................................................................................

5

            

    3.2  Terminals ........................................................................................................................................................

5

    3.3  Adapter Menu ................................................................................................................................................

6

4.  SETTING INTO OPERATION

 ................................................................................................................................

8

5.  TESTING MODES DISPLAY DATA OUTPUT OF VOLTAGE REGULATORS

 ....................................................

8

     5.1  Display Data Output when Testing an Alternator or a Voltage Regulator
            with COM Terminal .....................................................................................................................................

8

     5.2  Display Data Output when Testing an Alternator or a Voltage Regulator 
             with RLO, P-D, SIG, C Terminals .............................................................................................................

9

     5.3  Display Data Output in Ohmmeter Mode ............................................................................................

9

      

5.4  Display Data Output in PWM Generator Mode ...................................................................................

9

       

6.   STEP-BY-STEP INSTRUCTION

 ..........................................................................................................................

9

      6.1  Alternator or Voltage Regulator Testing ..............................................................................................

10       

      

6.2  Ohmmeter Mode .........................................................................................................................................

10     

      

6.3  PWM Signal Generator Mode ...................................................................................................................

10

7.   TEST CERTIFICATE

 ................................................................................................................................................

11

CONTENTS

User Manual - Tester MSG MS013 COM

Summary of Contents for MSG MS013 COM

Page 1: ...ADAPTER FOR ADJUSTMENT OF VOLTAGE REGULATORS QUA LIT Y UNIQUENE S S INNOVAT ION T R A INING SERV ICE WA R R A NT Y USER MANUAL MSG MS013 COM 2017 05 16 ...

Page 2: ...Alternator or a Voltage Regulator with COM Terminal 8 5 2 Display Data Output when Testing an Alternator or a Voltage Regulator with RLO P D SIG C Terminals 9 5 3 Display Data Output in Ohmmeter Mode 9 5 4 Display Data Output in PWM Generator Mode 9 6 STEP BY STEP INSTRUCTION 9 6 1 Alternator or Voltage Regulator Testing 10 6 2 Ohmmeter Mode 10 6 3 PWM Signal Generator Mode 10 7 TEST CERTIFICATE 1...

Page 3: ...ntrol modes of modern alternators Adapter is controlled by clock encoder with button to install and change parameters Installation and parameter data appear on LCD display The tester possesses the opportunity to change existing and implement new functions and interfaces in the software Update download is carried out through USB port Built in power supply gives an opportunity to use the device as h...

Page 4: ...e V 12 Tested parameters Stabilizing voltage COM voltage regulators protocol speed of exchange regulator type errors Voltage meter accuracy V 0 1 Short circuit protection Yes Connection terminals COM LIN BSS P D DFM RLO C SIG Additional functions PWM signal generator Yes Ohmmeter Yes 2 TECHNICAL CHARACTERISTICS User Manual Tester MSG MS013 COM ...

Page 5: ...ms increase function in the selected mode Down button Used to select the required option in the adapter menu Performs decrease function in the selected mode Confirmation button of mode selection Testing mode exit button 3 1 Buttons User Manual Tester MSG MS013 COM Fig 1 MS013 COM front view ...

Page 6: ...nerator 3 3 Adapter Menu COM testing of voltage regulators or alternators with BSS or LIN terminals The main connection ports of the terminals are displayed on the screen RLO testing of voltage regulators or alternators with RLO terminal The connection port of the terminal is displayed on the screen Used to connect voltage regulator control terminals COM LIN BSS RLO P D C SIG Used to connect a mea...

Page 7: ...inal The connection ports of the terminal are displayed on the screen P D testing of voltage regulators or alternators with P D terminals The connection ports of the terminals are displayed on the screen PWM PWM signal generator PWM signal generator connection scheme is displayed on the screen Ohm ohmmeter Ohmmeter connection scheme is displayed on the screen User Manual Tester MSG MS013 COM ...

Page 8: ...ith COM Terminal TYPE voltage regulator connection type Data is displayed in LIN and BSS protocols and can be of А and B type ID voltage regulator identification number varying from 1 to 254 BOD data exchange speed of a voltage regulator with car ECU The speed in BSS protocol is 2400 Low in LIN protocol it can be 2400 Low 9600 Average 19200 High PROTOCOL BSS or LIN voltage regulator protocol is di...

Page 9: ...lternator load control indicator Vol Reg set voltage indicator Voltage is set with UP and DOWN buttons 5 3 Display Data Output in Ohmmeter Mode OHMMETER resistance indicator Resistance is displayed in Ohm 5 4 Display Data Output PWM Generator Mode PWM percentage of duty cycle set varying from 0 to 100 FREQUENCY Hz frequency set displayed in Hertz with variation from 0 to 1000 Frequency and PWM is ...

Page 10: ... Enter the required testing mode with button Follow the display data set voltage with UP and DOWN buttons To exit the testing mode press button Disconnect the wires 6 2 Ohmmeter Mode Select the required option in the adapter menu with buttons Enter the required testing mode with button Connect GC and wires of the adapter outputs to measured resistance To exit the testing mode press button Disconne...

Page 11: ... the required numbers Set frequency by pressing the corresponding frame on the touch screen The lighting of the buttons will change use buttons to set the required numbers To exit the testing mode press button Disconnect the wires User Manual Tester MSG MS013 COM 7 TEST CERTIFICATE Tester MSG MS013 СОМ for adjustment of voltage regulators meets technical requirements of Directive 2014 30 EU Electr...

Page 12: ......