Version 1.0
4
Antenna heating system SOA-1022
1
DESCRIPTION AND OPERATION OF THE PRODUCT
1.1
Description
AHS is applied at onshore facilities, as well on sea- and river-going vessels.
The System ensures:
automatic heating of antennae installed on open deck to protect them against
low temperature using antenna heating units (hereinafter – AHU);
main/standby power switching using CSAHS and additional КРs;
temperature set up and control inside each AHU (dome) using a repeater via
digital interface RS-422;
connection of more than one AHU to one CSAHS applying КР. Maximum
number of connected AHUs to one CSAHS – 20 pcs.
1.2
Technical specifications
Tables 1–5 describe technical specifications of the System and SC.
Table 1 – Main technical specifications of AHS
Parameter
Value
Main (standby) electric power supply:
voltage, V
frequency, Hz
220
50
Max. power budget, kW
4.4
Operating temperature, °C
–52 to +60
Limiting temperature, °C
–60 to +70
Max. maintained temperature inside dome, °С
(at ambient temperature –52 °С)
–6
Table 2 – Main technical specifications of AHU
Parameter
Value
with dome
w/o dome
Electrical power supply:
voltage, V
frequency, Hz
220
50
Max. power consumption, W
AHU-1
AHU-2
AHU-3
400
600
1000
Operating temperature, °C
–52 to +60
Limiting temperature, °C
–60 to +70
Protection degree
IP56
–