Version 1.0
6
Antenna heating system SOA-1022
Table 5 – Main technical specifications of КР
Parameter
Value
Total number of terminals
8
Number of terminals to connect consumers
7
Max. permissible voltage, V
220
Max. permissible current, А
20
Operating temperature, °C
–15 to +55
Limiting temperature, °C
–60 to +70
Protection degree
IP56
Weight, kg
1.9
Overall dimensions (L х H х W), mm
278 x 148 x 52
1.3
The System components
Table 6 describes the list of SC included in the System.
Note – Exact quantity of AHU and КР is defined at delivery and depends on the
customer’s facilities.
Table 6 – The System components
Name
Description
Notes
CSAHS
Main/standby input voltage switching, 220 V AC,
frequency 50 Hz per load
AHU
Antennae heating.
Antennae
protection
against
atmospheric
precipitation
With dome
Antennae heating
W/o dome
Repeater
Temperature set up and control inside each AHU
(dome).
Visual control over AHU parameters and
conditions
КР
Connection of 2 to 20 AHUs to one
CSAHS
To power AHU and CAN bus
connection
Depending on the applied SC the System may have four types (Table 7).