Version 1.0
18
Antenna heating system SOA-1022
Parameter
Default value
Описание
Прирост температуры
t
п
за время T
н
, °С
1.0
Temperature inside dome is to be increased by this value
for the specified heating time T
н
Максимальное
различие датчиков
|t1-t2| , °С
10.0
Max. difference between two temperature sensors, where
t1 – readings of first sensor, t2 – readings of second
sensor.
If readings exceed the preset value, warning is displayed
Время выхода на
постоянную мощность
Т
пс
, с
2.0
Time after start of heating to test TH power
Время на тест Т1, с
5.0
Time to test the System.
Set 0.0 to disable this option
Период
автоматического
тестирования Т2, с
86400.0
Time for the System self-test (obligatory)
Коэффициент
измерителя тока Kcur
1.000
Coefficient to correct TH power values. Set up by the
manufacturer’s representative while providing primary
settings
Датчик 1 (Д1)
Датчик 2 (Д2)
On
On
If one of the sensors has
wrong readings, it may be
disconnected.
Calculations consider minimum value from the values of
both sensors
Канал 1
Канал 2
Канал 3
Канал 4
On
On
On
On
One channel corresponds to one connected TH
Текущая версия
V1.3.2
Software version of the selected AHU (this line appears
only while editing one AHU)
Default parameters include button “Отправить параметры на все ПОА”;
press this button to send the selected parameters to all connected AHUs. To change
parameters of a single AHU, choose it in the list and press “
”.
While editing, “Обновление прошивки” button that may be used only by the
manufacturer’s representative is active.
Menu “Настройки”
Menu “Настройки” is used by manufacturer’s representative while providing
primary settings of the Product. Figure 12 describes this menu.