1

1

Important document – retain for future use

MSA

safety

.com

MSA

 Latchways Personal Rescue 

Device® (Latchways PRD®)

User Instructions 

CSA Z259.2.3-16/1/D
ANSI Z359.4-2013

Summary of Contents for Latchways Personal Rescue Device

Page 1: ...1 1 Important document retain for future use MSAsafety com MSA LatchwaysPersonalRescue Device LatchwaysPRD User Instructions CSA Z259 2 3 16 1 D ANSI Z359 4 2013...

Page 2: ...gements adopted in respect of this item conforms to the conditions of EN ISO 9001 2008 Issue date dd mm yy Place Devizes UK 4 Signed inspection stamp Manufactured by Latchways plc Hopton Park Devizes...

Page 3: ...nt height 65 ft 20 m Descent energy 25 300 ft lbF 34 300 J Descent line type 3 16 in 5 4 mm diameter Ultra High Molecular Weight Polyethylene UHMwPE core Aramid overbraid rope Personnel requirements T...

Page 4: ...he plan must take into account the equipment and specific training necessary to affect prompt rescue under all foreseeable conditions If the rescue be from a confined space the provisions of OSHA regu...

Page 5: ...hat the load line webbing is looped around the release pin Figure 7 Ensure that the green release pin clip is present and undamaged check for signs of damage distortion or cracking Figure 7 Ensure tha...

Page 6: ...rinse thoroughly with fresh clean water then remove excess water with a dry cloth Allow to dry naturally away from direct heat then examine fully before storing or returning to use 2 3 4 1 Check the g...

Page 7: ...PRD descender device certificat de conformit voir page 3 Aucune partie de ce document ne peut tre reproduite ou transmise sous quelque forme ou par quelque proc d que ce soit sans l autorisation pr al...

Page 8: ...tilisation Num ro de mod le du descendeur 68220 Hauteur de descente maximum 65 ft 20 m nergie de descente 25 300 ft lbF 34 300 J Type de corde de descente 3 16 in 5 4 mm diameter Ultra High Molecular...

Page 9: ...rs lors de la descente assurez vous que la distance de descente est inf rieure ou gale 20 m 65 ft Il ne faut pas atterrir sur la partie inf rieure d une structure lors de la descente Cela peut cr er d...

Page 10: ...hways PRD descender device hors service et consultez MSA ou un repr sentant agr Apr s l inspection fermez compl tement la fermeture clair du sac dos Figure 8 Figure 6 Examinez la corde de descente pou...

Page 11: ...ure 11 1 Utilisation du Latchways PRD descender device Actionnement du dispositif individuel de sauvetage Pendant une descente il peut tre possible d atterrir de mani re s curis e sur une partie inf r...

Page 12: ...r qui d clenche une descente Sac dos sac en tissu fix au harnais contenant le dispositif de descente Ancrage dispositif d ancrage antichute ayant une capacit minimale de 12 kN Harnais harnais int gral...

Page 13: ...bajo de forma segura El dispositivo de Latchways PRD descender device solo puede utilizarse para un descenso Una vez activado la velocidad de descenso se limita autom ticamente y no requiere ninguna a...

Page 14: ...e individual Latchways PRD pueden calentarse Deje que se enfr en antes de abrir la mochila No intente desmontar el equipo de rescate individual Latchways PRD del arn s El equipo de rescate individual...

Page 15: ...s PRD descender device y p ngase en contacto con MSA o con un agente autorizado Despu s de la inspecci n cierre la cremallera de la mochila completamente Figura 8 Cord n Util cese siempre un cord n qu...

Page 16: ...inspecciones peri dicas con mayor frecuencia La inspecci n peri dica debe registrarse en el registro de inspecci n peri dica Las instrucciones para el examen peri dico ref 68201 97PE pueden descargar...