background image

ULTRA ELITE FACEPIECE

iv. There is no loose play in the assembly of parts.

4. For Firehawk slide-to-connect facepieces.

a. Thread the adapter into the facepiece.
b. Tighten the adapter hand tight. Use the component

housing cover to continue to tighten until the top
flat on the octagon is horizontal.

c. Insert the tab on the component housing cover into

the slot in the lens ring.

d. Press in on the front of the cover until the cover

hook snaps in place.

e. Place the neckstrap brackets in the cover sockets.
f. Install and tighten the Phillips screws.
g. Verify that there is no loose play in the assembly of

parts.

5. For Firehawk push-to-connect (PTC) facepieces:

a. Insert the component housing cover tab into the

lens ring slot, leave the cover loose.

b. Place the PTC adapter through the facepiece com-

ponent housing cover and thread the adapter
assembly into the facepiece hand tight.

c. Continue to tighten until the top flat of the adapter

octagon is horizontal.

Note:

The octagon flats on the facepiece adapter must

align with octagon flats of component housing.

d. Press in on the front of the cover until the cover

hook snaps into place.

e. Place the neckstrap brackets into the cover sock-

ets.

f. Install the phillips screws and tighten.
g. Verify that there is no loose play in the assembly of

parts.

6. Don the facepiece and check the face-to-facepiece

seal. Follow the facepiece fit check procedures in the
user’s instructions.

Note:

For questions regarding this procedure, please

contact MSA Customer Service at 1-877-MSA-3473.

12

TAL 805 (L) Rev. 4 - 10042830

Facepiece Components

Firehawk Push-to-Connect

Adapter and Component Housing

Cover

Firehawk Slide-to-Connect

Adapter and Component Housing

Cover

Air Purifying and Pressure Demand

(Except MMR and Firehawk)

Adapter and Component

Housing Cover

Component Housing Cover

Removal Not Necessary

Screws

Locking Ring

Spacers

Gasket (Valve Spider)

Inlet Disc Valve

Neckstrap

MMR Component Housing Cover

MMR Adapter

Facepiece

Summary of Contents for FireHawk Ultra Elite 10048813

Page 1: ...Ultra Elite Facepiece TAL 805 L Rev 4 MSA 2008 Prnt Spec 10000005389 I Mat 10042830 Doc 10000015248 MAINTENANCE AND REPAIR...

Page 2: ...811 Component Housing Ring 14 804812 Screw Kit 15 10018621 Slide Adapter Ass y 15a 10033115 Push To Connect Adapter Ass y 15b 813556 1 4 Turn Adapter Ass y 17 804829 Neckstrap 18 815604 Component Hous...

Page 3: ...10042830 ULTRA ELITE FACEPIECE 7a 7 7b 15b 23 24 3 12 27 in lbs pressure demand facepiece NFPA Facepiece Components Type Small Medium Large Hycar 10048814 10048813 10048815 Silicone 805581 805580 8055...

Page 4: ...4 TAL 805 L Rev 4 10042830...

Page 5: ...operly Note Do not force dry the parts by placing them in a heater or in direct sunlight The rubber will deteriorate When the facepiece is thoroughly dry store the facepiece in the plastic bag that it...

Page 6: ...ng freeing retainer from slots in the housing Lift the retainer and the spring out of the component hous ing Discard spring and spring retainer Be careful not to damage the slots or valve seat in the...

Page 7: ...he octagon flange on the adapter b Thread the adapter assembly into the facepiece Use the spanner wrench to torque the adapter to 12 27 in lbs If necessary continue to torque until the top flat on the...

Page 8: ...the groove Work the face piece rubber flange around the lens to fully seat the lens in the groove When installed correctly the bottom lens center line mark lines up with the bottom face piece center...

Page 9: ...ea and the inside of the housing ring 4 Insert the narrow end of the ring into the space between the lower lens ring and the facepiece housing area 5 Line up the component housing ring mark with the f...

Page 10: ...2 Remove the disc from the gasket and inspect both for wear The disc should be very soft and pliable Install a new disc valve if it is damaged or hardened 3 To install the inhalation disc valve a Gen...

Page 11: ...Housing Cover and Adapter 1 Gently stretch the hole in the center of the inlet disc valve over and onto the gasket stem 2 With the pull tab facing outward insert the gasket into the facepiece at an an...

Page 12: ...ontinue to tighten until the top flat of the adapter octagon is horizontal Note The octagon flats on the facepiece adapter must align with octagon flats of component housing d Press in on the front of...

Page 13: ...pter through the facepiece component housing cover Thread the adapter assembly into the facepiece 3 Tighten facepiece adapter until the top flat on the octagon is horizontal Note The octagon flats on...

Page 14: ......

Reviews: