background image

Additional Information 

 
 
 

 

Gardner Denver Driver Manual 

13 

 
 

Reference 

8.1

 

Data Storage Format 

Offset 

Description 

Units 

DA_Service_Data 

Advisories 

see ES/RS2000 Controller spec 

1-20 

10x (Shutdown code / Hourmeter reading) pairs   see ES/RS2000 Controller spec 

21 

Current total runtime hourmeter reading 

Hours 

22 

Current loaded runtime hourmeter reading 

Hours 

23-28 

6x Current temp hourmeters [H1] 

– [H6] 

Hours 

29-34 

6x Stored temp hourmeters [OH1] 

– [OH6] 

Hours 

35 

Last maintenance A 

Hours 

36 

Last maintenance B 

Hours 

37 

Oilage 

Unknown, see ES/RS2000 controller spec 

Operating Mode Data 

Operating mode indication 

see ES/RS2000 Controller spec 

Sequence number

2

 

see ES/RS2000 Controller spec 

Unit operating state

3

 

see ES/RS2000 Controller spec 

Operating Data 

System pressure 

divide by 16 for pressure in psig 

Filter pressure 

divide by 16 for pressure in psig 

Discharge temperature 

divide by 16 for temperature in degrees F 

Reservoir temperature 

divide by 16 for temperature in degrees F 

Motor current

4

 

amps 

 

 

 

2

 ES V2.0X Controllers do not respond with this field. 

3

 ES V2.0X Controllers do not respond with this field. 

4

 RS2000 V4.0X Controllers set this field to zero. 

Summary of Contents for fieldserver FS-8700-60

Page 1: ...er Denver Driver Manual 0 Driver Manual FS 8700 60 Gardner Denver MSAsafety com Driver Revision 1 03 Document Revision 3 A APPLICABILITY EFFECTIVITY Effective for all systems manufactured after March...

Page 2: ...A Safety 1991 Tarob Court Milpitas CA 95035 Website www MSAsafety com U S Support Information 1 408 964 4443 1 800 727 4377 Email smc support msasafety com EMEA Support Information 31 33 808 0590 Emai...

Page 3: ...ameters 8 5 2 Client Side Node Descriptors 8 5 3 Client Side Map Descriptor Parameters 9 5 3 1 FieldServer Specific Map Descriptor Parameters 9 5 3 2 Driver Related Map Descriptor Parameters 9 5 3 3 T...

Page 4: ...e driver does not validate the message data fields for correct values although it does validate data field lengths for example shutdown codes reported by V2 1 ES Controllers range from 0 to 27 If a co...

Page 5: ...ons The FieldServer is connected to the ES RS2000 Controller as shown in the connection drawing below Configure the ES RS2000 Controller according to manufacturer s instructions RS 485 Connection Gard...

Page 6: ...e White Rx Tx GND Brown Connect to the RS 232 port on the FieldServer FS 8917 03 Pinouts FS Function DB9F Pin TX 2 RX 3 GND 5 CTS 8 3 1 Hardware Connection Tips Hints If inter controller communication...

Page 7: ...Title Function Legal Values Data_Array_Name Provide name for Data Array Up to 15 alphanumeric characters Data_Format Provide data format Each Data Array can only take on one format Float Bit Byte Uint...

Page 8: ...Baud Specify baud rate 1200 9600 match to Controller Parity Specify parity Odd Even None Data_Bits Specify data bits 7 8 Stop_Bits Specify stop bits 1 2 Poll_Delay Time between internal polls 0 2s 0 2...

Page 9: ...alues Node_Name Name of Node to fetch data from One of the node names specified in Client Node Descriptor above Gar_Cmd Data poll commands Service_Data Operating_Mode Operating_Data Gar_Data Data fiel...

Page 10: ...ple Function Active Read Block Continuous Map Descriptor function responsible for polling the Controller Gar_Cmd The Gar_Cmd field is used to select the data to poll Gar_Data The Gar_data field is set...

Page 11: ...matching Node_Name and Gar_Cmd fields It then stores the data items as specified by the Gar_data field from the data collected by the preceding active Map Descriptor 6 2 Poll Data Length The length o...

Page 12: ...lect Unit Polls for Single Units Connected The device must be in Sequence Mode not Standalone mode The unit can be put in sequence mode setting the Units in Sequence to a number greater than 1 If usin...

Page 13: ...aintenance B Hours 37 Oilage Unknown see ES RS2000 controller spec Operating Mode Data 0 Operating mode indication see ES RS2000 Controller spec 1 Sequence number2 see ES RS2000 Controller spec 2 Unit...

Reviews: