Attention!
When being pressurised, cylinder must not be swivelled as this can
cause damage to the
alphaCLICK 2
filling
coupling.
This is particularly important if a water basin for cooling is used while
filling.
(4) Fill the compressed air cylinder using the operating lever.
(5) Once the compressed air cylinder has been filled, close the cylinder valve.
(6) Depressurise the connection between the filling panel and the cylinder.
(7) Turn the handwheel of the
alphaCLICK 2
filling coupling on the filling panel
clockwise first and upon reaching the stop, press in the direction of the filling
panel.
•
The cylinder adaptor is released from the
alphaCLICK 2
filling coupling.
(8) Remove compressed air cylinder from the
alphaCLICK 2
filling coupling.
(9) Secure the
alphaCLICK 2
filling coupling with blind plug.