background image

12

TAL 013 (L) Rev. 10 - 10028994

NOTES

Summary of Contents for Advantage 3100

Page 1: ...Advantage 3000 Series Respirator P N 818082 CS CN This manual must be carefully read and followed by all persons who have or will have the responsibility for using or servicing Advantage 3000 APR Res...

Page 2: ...iguration as speci fied by the manufacturer O Refer to User s Instructions and or maintenance man uals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators...

Page 3: ...l warnings and limitations specified 16 Wear impermeable protective clothing to prevent exposure to gases and vapors which can poison by skin absorption 17 Do not use this full facepiece with self con...

Page 4: ...respirators before reuse in accor dance with the instructions provided This respirator filter is NOT for use by a children or b people with a medical condition that may be adversely affected by using...

Page 5: ...left head harness attachment These facepieces do not pertain to the NIOSH approved CBRN application Contact MSA at 1 800 MSA 2222 for the correct facepiece Failure to follow this warning can result in...

Page 6: ...l chloride diisocyanate Methylene chloride containin paints Nickel carbonyl Vinyl chloride Nitric Acid 6 TAL 013 L Rev 10 10028994 Canister for Chin Type Gas Masks Maximum Escape Part No MSA Canister...

Page 7: ...P100 Canister must be replaced after each use against hydrogen flu oride not to exceed 12 hours to ensure the integrity of the P100 filter F MULTI USE LIMITATIONS OptiFilter XL only 1 Approved as a h...

Page 8: ...8 TAL 013 L Rev 10 10028994 NOTES...

Page 9: ...ned to ensure proper fit before using the respirator If other than facial seal leakage is detected the condition must be investigated and corrected before another test is made The respirator must also...

Page 10: ...10 TAL 013 L Rev 10 10028994 NOTES...

Page 11: ...n opening the bag For gas mask canister refer to the shelf life sec tion for storing the canister outside the packaging Discard canister cartridge s after each use Replace the canister cartridge s aft...

Page 12: ...12 TAL 013 L Rev 10 10028994 NOTES...

Page 13: ...e flat against the top of head Note Both top straps should be adjusted with button in the same position so straps are equal in length 7 If the mask does not feel snug up against face loosen the bottom...

Page 14: ...he test as follows 1 Ensure respirator is assembled properly 2 Block off canis ter cartridge s inlet using the palm s of the hand s 3 Inhale gently and hold breath for 10 seconds If the seal is good t...

Page 15: ...cover tab disengaging the com ponent housing tab 2 Slide the cover up to remove it from top tabs of the component housing 3 To install the cover insert the top tab of component housing into the top s...

Page 16: ...ts on the back of the Lens bayonet connectors and gently stretch the valve openings to slip over the posts For Model 3100 a To replace the inhalation valves on the spider gas ket line up the holes in...

Page 17: ...o screws which secure the lens rings 2 Separate the lens rings 3 Fold back the facepiece blank and remove the lens LENS REASSEMBLY Before installing a new lens check the blank groove for dirt or other...

Page 18: ...button snaps into the button hole 3 Make sure the strap is not twisted and that the boss on end tabs side is facing up away from the inside of the facepiece 4 Thread the end tabs with the boss facing...

Page 19: ...nd tabs side is facing up away from the inside of the mask 3 Don the mask and perform the Tightness Test Adapter Clips Reassembly Note All procedures are from face side of mask 1 The adapter clips are...

Page 20: ...20 TAL 013 L Rev 10 10028994 NOTES...

Page 21: ...must be per formed Disposal is to be performed as required by feder al state and or local laws PROCEDURE FOR REMOVING THE RESPIRATOR 1 To remove the facepiece insert your thumbs under each of the har...

Page 22: ...22 TAL 013 L Rev 10 10028994 NOTES...

Page 23: ...tions with the Confidence Plus Cleaning Solution b If the Confidence Plus Cleaning Solution is not used wash in a mild cleaning solution rinse thor oughly and submerge in a germicide solution for the...

Page 24: ...24 TAL 013 L Rev 10 10028994 NOTES...

Page 25: ...sing the supplied cap plug component Remove the canister from the box and bag Locate the white block on the canister label Mark on the canister in the white block an expiration date of 1 year for form...

Page 26: ...er must be attached to the facepiece with the plug side of the cap and plug component secured into position DO NOT store the canister above 120 F Failure to fol low this warning can alter the performa...

Page 27: ...through MSA Adjusting the Spectacles 1 To move the spectacles closer to your face pull the frame prongs out of the rubber block 2 To move the spectacles farther from your face push the frame prongs in...

Page 28: ...spirator can be used in other configurations that stated in these User s Instructions Below is a list of these other configurations and the part number for the User s Instructions Review the NIOSH mat...

Page 29: ...Refer to separate NIOSH Approval insert for approval information 29 TAL 013 L Rev 10 10028994...

Page 30: ...30 TAL 013 L Rev 10 10028994 Refer to separate NIOSH Approval insert for approval information...

Page 31: ...ve of MSA may bind MSA to any affirmation representation or modification of the warranty con cerning the goods sold under this contract MSA makes no warranty concerning components or acces sories not...

Page 32: ......

Reviews: