25
Cleaning and Disinfecting
PremAire Cadet Escape G1
US
NOTE
: When the facepiece is thoroughly dry, store the facepiece in the plastic bag that it was shipped
in.
(1)
Remove the facepiece mounted regulator from the face-
piece.
(2)
Submerge the facepiece in Confidence Plus Cleaning
Solution. A soft brush or sponge can be used to clean the
soiled facepiece.
(3)
Rinse the facepiece and components in clean, warm
(110°F (43°C)) water (preferably running and draining).
(4)
Be sure to clean and rinse the pressure-demand exhala-
tion valve by pressing in on the stem with a blunt object
and flushing it with clean water.
(5)
Allow the facepiece to air dry. Do not dry the parts by placing them near a heater or in direct
sunlight.
(6)
Operate the exhalation valve by hand to be sure it works properly.
(7)
Thoroughly dry the facepiece and regulator after cleaning and disinfecting. The facepiece can
trap water that could enter the regulator.
(8)
Perform a tightness test before putting the facepiece back in service.