Configuring the LX-8000 Series for the First Time
26
MRV Communications, Inc.
www.mrv.com
451-0331
1. Plug in the terminal at the DIAG port (port 0 - port values are 9600 bps, eight data bits, one stop bit, no
parity, and Xon/Xoff flow control). The Main Menu appears.
2. Press
b
to boot the LX-8000 unit. The setup takes a minute or two. The
The unit has loaded
to factory defaults, would you like to run Initial Connectivity Setup? y/n
message appears.
3. Press
y
(yes) and press Enter. The
“Enter your superuser password”
message appears, fol-
lowed by the Superuser Password prompt.
4. Enter superuser password
system
. The Quick Configuration menu appears:
5. Press the number corresponding to the parameter you want to set.
6. Enter the appropriate information and press <Enter> to return to the Quick Configuration menu.
Once you enter a parameter value, a data entry line specific to that parameter appears on the
Quick Configuration menu.
7. Continue in this way through the menu, configuring as many parameters as you want. You are
not required to configure all parameters.
NOTE:
You should change the Superuser Password, since this is the first time you are configuring
the LX-8000 unit (the default password is
system
). The login username and password are
case-sensitive.
Quick Configuration menu
1 Unit IP address
2 Subnet mask
3 Default Gateway
4 Domain Name Server
5 Domain Name Suffix
6 Cluster Secret
7 Superuser Password
8 Exit and Save
Enter your choice:
Summary of Contents for LX-8000 Series
Page 4: ...4 MRV Communications Inc www mrv com 451 0331 ...
Page 8: ...8 MRV Communications Inc www mrv com 451 0331 ...
Page 10: ...10 MRV Communications Inc www mrv com 451 0331 ...
Page 24: ...Installing the LX 8000 Series 24 MRV Communications Inc www mrv com 451 0331 ...
Page 44: ...Alternative Port Capabilities 44 MRV Communications Inc www mrv com 451 0331 ...
Page 48: ...Appendix A Technical Specifications 48 MRV Communications Inc www mrv com 451 0331 ...