Appendix C - POST Test Error Codes
Error Code Definitions
The following table provides the definitions for the LX-8000 Series POST test error codes.
Table 4 - POST Test Error Codes
Error Definition
Error Code (in Hexa-
decimal)
Real Time Clock does not work properly
1010
Reading Invalid Default Value from CPLD Diagnostic Register
2010
Reading Invalid Default Value from Expansion CPLD Diagnostic Register
2011
Reading Invalid Pattern Value from CPLD Diagnostic Register
2020
Reading Invalid Pattern Value from Expansion CPLD Diagnostic Register
2021
Reading Invalid Value from CPLD System Fail Status Register
2030
AC FAIL bit is set in the CPLD System Fail Status Register
2031
+12VFAIL bit is set in the CPLD System Fail Status Register
2033
-12VFAIL bit is set in the CPLD System Fail Status Register
2034
CPLD FAIL bit is set in the CPLD System Fail Status Register
2035
DC_A bit is set in the CPLD System Fail Status Register
2037
DC_B bit is set in the CPLD System Fail Status Register
2038
Watchdog Timer Failed
2040
Invalid HW Type
2050
Fast Ethernet Controller (FEC) Reset Delay Timeout
3010
Fast Ethernet Controller (FEC) Transmission Failed Timeout
3020
Summary of Contents for LX-8000 Series
Page 4: ...4 MRV Communications Inc www mrv com 451 0331 ...
Page 8: ...8 MRV Communications Inc www mrv com 451 0331 ...
Page 10: ...10 MRV Communications Inc www mrv com 451 0331 ...
Page 24: ...Installing the LX 8000 Series 24 MRV Communications Inc www mrv com 451 0331 ...
Page 44: ...Alternative Port Capabilities 44 MRV Communications Inc www mrv com 451 0331 ...
Page 48: ...Appendix A Technical Specifications 48 MRV Communications Inc www mrv com 451 0331 ...