User Manual
VARIO
luxx
52 / 129
MRU GmbH, D-74172 Neckarsulm
6
Measurement
6.1.
Preparing measurement
CAUTION
Acid from the condensate
Acid burns may result from weakly acidic liquids from the
condensate.
►
If you come into contact with acid, wash the area im-
mediately using a lot of water.
►
Note the safety data sheet for phosphoric acid (10%).
DANGER
Risk due to toxic gases
There is a risk of poisoning.
Noxious gases are sucked in by the measuring device
and released into the ambient air.
►
Only use the measuring device in well ventilated
spaces.
Setting up the measuring point
►
Place the analyser on a stable surface.
►
Unroll the heating hose completely.
►
Ensure that the heating hose is not twisted in itself.
►
Ensure that all couplings and hose connectors are properly
connected.
NOTE
Please note that heating hoses with 110V and 230V are
offered.
►
Check the voltage supply of the heating hose before
commissioning.
►
You can operate a 230V heating hose with 110 volts,
but with limited heat capacity.
DANGER
Risk due to improper use
Risk of death due to electric shock
►
Do not operate a 110V heating hose with 230V.