Adjusting Speed With The Flow Control Valve
1.
Adjust the flow control valve to the desired speed.
2. Adjust the dial (A) downward to increase spreader plate rotation.
3.
Travel forward in the operating area, adjusting hopper doors and flow
control valve speed as needed.
Reversing Spreader Plate Rotation
You can switch the hoses in the hydraulic motor ports so the spreader
plate will rotate in a counterclockwise direction. If you do so, door #2
must remain closed when operating (See Adjusting the Hopper Doors).
1. Remove the attachment from the loader.
2. Use a safe lifting device to raise the attachment high enough to ac-
cess the hydraulic motor area. Block the raised attachment.
3.
Position a drain pan under the motor to catch any fluid.