Troubleshooting 4
2. General Troubleshooting
2.1 Error Display (Indoor Unit)
When the indoor unit encounters a recognized error on different models ,
1. the running LED with flash in a corresponding series, the timer LED may turn on or begin flashing;
2. an error code will be displayed;
3. both 1 and 2.
These error codes are described in the following tables:
Running
Lamp
Timer
Lamp
Display
Information
Solution
--
--
F
Defrost
Normal
Display, not
error code
--
--
CL
Filter cleaning reminder(power on display for 15 seconds)
--
--
CL
Active clean
--
--
F
Filter replacement reminder(power on display for 15 seconds)
--
--
FP
Heating in room temperature under 8°C
--
--
FC
Forced cooling
--
--
AP
AP mode of WIFI connection
--
--
CP
Remote switched off
1 time
OFF
EH 00
Indoor unit EEPROM parameter error
TS27
2 times
OFF
EL 01
Indoor/outdoor units communication error
TS28
3 times
OFF
EH 02
Zero-crossing signal detection error(for some models)
TS45
4 times
OFF
EH 03
The indoor fan speed is operating outside of the normal range
TS31
5 times
OFF
EC 51
Outdoor unit EEPROM parameter error
TS27
5 times
OFF
EC 52
Condenser coil temperature sensor T3 is in open circuit or has short
circuited
TS33
5 times
OFF
EC 53
Outdoor room temperature sensor T4 is in open circuit or has short
circuited
TS33
5 times
OFF
EC 54
Compressor discharge temperature sensor TP is in open circuit or
has short circuited
TS33
5 times
OFF
EC 56
Evaporator coil outlet temperature sensor T2B is in open circuit or
has short circuited(for free-match indoor units)
TS33
6 times
OFF
EH 60
Indoor room temperature sensor T1 is in open circuit or has short
circuited
TS33
6 times
OFF
EH 61
Evaporator coil middle temperature sensor T2 is in open circuit or
has short circuited
TS33
12 times
OFF
EC 07
The outdoor fan speed is operating outside of the normal range
TS31
7 times
FLASH
PC 00
IPM malfunction or IGBT over-strong current protection
TS36
2 times
FLASH
PC 01
Over voltage or over low voltage protection
TS38
3 times
FLASH
PC 02
Top temperature protection of compressor or High temperature
protection of IPM module or High pressure protection
TS46
5 times
FLASH
PC 04
Inverter compressor drive error
TS36
1 time
FLASH
PC 08
Current overload protection
TS34
7 times
FLASH
PC 03
High pressure protection or low pressure protection
TS47/TS49
1 times
ON
--
Indoor units mode conflict(match with multi outdoor unit)
--
Summary of Contents for DIY-MULTI2-18HP230C
Page 1: ...4TH GENERATION MULTI ZONE SERVICE MANUAL...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Page 20: ...5 8...
Page 21: ......
Page 22: ......
Page 24: ...Outdoor unit printed circuit board diagram 17122000051368...
Page 27: ...Outdoor unit printed circuit board diagram 17122300001076...
Page 29: ...Outdoor unit IPM board diagram 17122000018251...
Page 31: ...Outdoor unit printed circuit board diagram 17122000037804...
Page 33: ...Outdoor unit IPM board diagram 17122000042012...
Page 42: ...Outdoor Unit Disassembly 3 2 Dimension 2 1 Panel Plate B30 1 drive 2...
Page 43: ...Outdoor Unit Disassembly 4 2 2 Panel Plate CA30 1 drive 2 1 drive 3 1 drive 4...
Page 44: ...Outdoor Unit Disassembly 5 2 3 Panel Plate CA30 1 drive 2 for US models...
Page 45: ...Outdoor Unit Disassembly 6 2 4 Panel Plate D30 1 drive 2 1 drive 3 1 drive 4 1 drive 5...
Page 46: ...Outdoor Unit Disassembly 7 2 5 Panel Plate D30 1 drive 3 1 drive 4 for US models...
Page 47: ...Outdoor Unit Disassembly 8 2 6 Panel Plate X330 1 drive 2...
Page 48: ...Outdoor Unit Disassembly 9 2 7 Panel Plate X430 1 drive 3...
Page 49: ...Outdoor Unit Disassembly 10 2 8 Panel Plate X430 1 drive 2 for US models...
Page 50: ...Outdoor Unit Disassembly 11 2 6 Panel Plate E30 1 drive 5 for US models...