Contents
1.
Safety Caution .......................................................................................................3
2.
General Troubleshooting ......................................................................................4
2.1
Error Display (Indoor Unit) ..............................................................................4
2.2
Error Display (Outdoor Unit) ...........................................................................6
3.
Complain Record Form ..........................................................................................7
4.
Information Inquiry ...............................................................................................9
5.
Outdoor Unit Point Check Function ...................................................................12
6.
Error Diagnosis and Troubleshooting Without Error Code ...............................18
6.1
Remote maintenance ...................................................................................18
6.2
Field maintenance .......................................................................................19
7.
Quick Maintenance by Error Code ......................................................................24
8.
Troubleshooting by Error Code ...........................................................................27
8.1
EH 00 /EC 51(EEPROM parameter error diagnosis and solution) ...................27
8.2
EL 01 (Indoor and outdoor units communication error diagnosis and solution) 28
8.3
EH 03 / EC 07 (Fan speed is operating outside of the normal range )/EC 71(Over
Current Failure of Outdoor DC Fan Motor) Diagnosis and Solution ...............31
8.4
EH 60/EH 61/EC 53/EC 52/EC 54/EC 56 /(ODU)E4/EC 50 (Open circuit or short
circuit of temperature sensor diagnosis and solution) ...................................33
8.5
PC 08(Current overload protection)/PC 44(Outdoor unit zero speed protection)/
PC 46(Compressor speed has been out of control)/PC 49(Compressor
overcurrent failure) diagnosis and solution ...................................................34
8.6
PC 00(IPM malfunction)&(IDU)PC 04(Inverter compressor drive error diagnosis
and solution) ...............................................................................................36
Troubleshooting
Summary of Contents for DIY-MULTI2-18HP230C
Page 1: ...4TH GENERATION MULTI ZONE SERVICE MANUAL...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Page 20: ...5 8...
Page 21: ......
Page 22: ......
Page 24: ...Outdoor unit printed circuit board diagram 17122000051368...
Page 27: ...Outdoor unit printed circuit board diagram 17122300001076...
Page 29: ...Outdoor unit IPM board diagram 17122000018251...
Page 31: ...Outdoor unit printed circuit board diagram 17122000037804...
Page 33: ...Outdoor unit IPM board diagram 17122000042012...
Page 42: ...Outdoor Unit Disassembly 3 2 Dimension 2 1 Panel Plate B30 1 drive 2...
Page 43: ...Outdoor Unit Disassembly 4 2 2 Panel Plate CA30 1 drive 2 1 drive 3 1 drive 4...
Page 44: ...Outdoor Unit Disassembly 5 2 3 Panel Plate CA30 1 drive 2 for US models...
Page 45: ...Outdoor Unit Disassembly 6 2 4 Panel Plate D30 1 drive 2 1 drive 3 1 drive 4 1 drive 5...
Page 46: ...Outdoor Unit Disassembly 7 2 5 Panel Plate D30 1 drive 3 1 drive 4 for US models...
Page 47: ...Outdoor Unit Disassembly 8 2 6 Panel Plate X330 1 drive 2...
Page 48: ...Outdoor Unit Disassembly 9 2 7 Panel Plate X430 1 drive 3...
Page 49: ...Outdoor Unit Disassembly 10 2 8 Panel Plate X430 1 drive 2 for US models...
Page 50: ...Outdoor Unit Disassembly 11 2 6 Panel Plate E30 1 drive 5 for US models...