27
7-8 After cleaning the water reservoir, water supply tube fixed in the bottom of the water
reservoir must be screwed firmly with water supply port of the unit.
Water supply tube
Water supply port
Note: O- ring is installed in the water supply tube.
Degradation and deformation of O-ring cause the leakage of the water, so
need to check O-ring when mounting the water reservoir, and replace with
new O-ring if needed.
O-ring
7-9 Installation of the water reservoir follows the reverse sequence.
Note: In order to avoid mishandling the unit, please set ‘’Off’’ for both switch panel
and earth leakage breaker.