13
Fault indication
1. Warning for water supply.
1-
1 When the water tank gets empty, ‘’FEED WATER’’ is shown in the display with
alarm and stop the unit automatically.
1-2 Fill water in the tank, and set back to the unit, then Error LED in the display and
alarm are disappeared then the unit restarts.
Note : Warning alarm can be switched off by pushing lock switch.
2. Exchange the UV lamp for air cleaning.
2-1 When UV lamps built in the air cleaning unit has exceeded the life time and no
lighting up the UV lamp, LED lights and showing the error message in the
display with alarm.
2-2 Replace the UV lamps, error message is disappeared after replace the UV
lamps, and restart the air cleaning operation. ( please refer P16 for
replacement of UV lamp )
* Warning alarm can be switch off by pushing the lock switch.