2. SPECIFICATIONS

2-1 General Specifications

Circuit

Custom one-chip of microprocessor
LSI circuit.

Display

Large LCD display Max. reading 9999.
LCD size :90.5 x 64.5 mm.
Dual value display with backlight.

Measurement

ACV

0 to 600.0 V

DCV

0 to 600.0 V

 to 20.00 k

WATT

0.1 W to 2500 W

Leakage 

0.01 m A to 80.00 m A

current
ACA

0.01 A to 10.00 A

Over input

" - - - - " mark indication .

Polarity 

Automatic switching , "-" indicates
reverse polarity.

Zero Adjustment Automatic adjustment.
Sampling Time

Approx. 1.5 second.

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Data output 

RS232 / USB PC Computer interface .
* Connect the optional RS232 cable

UPCB - 02 will get the RS232 plug .

* Connect the optional USB cable

USB - 01 will get the USB plug .

Operation 

0  to 50  (32 to 122 ) .

Temperature
Operation

Less than 80% RH.

Humidity

2

Summary of Contents for DW-6160

Page 1: ...sion measurement A l t h o u g h t h i s WATT Leakage METER is a complex and delicate instrument its durable structure will allow many years of use if proper operating t e c h n i q u e s a r e develo...

Page 2: ...emove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories II 600V Pollution Degree 2 Altitude up to 2000 m...

Page 3: ...AX MIN 6 3 4 Data hold button 6 3 5 Power function rotary switch 6 3 6 ACV DCV input terminal 6 3 7 Load terminal 6 3 8 Power source terminal 6 3 9 Battery Cover Compartment 6 3 10 Stand 6 3 11 RS 232...

Page 4: ...001 A 0 01 A DCV 600 0 V x 0 01 V 0 1 V 20 k x 0 01 k 0 001 k 1 Low Watt measurement 999 9 Watt x 0 1 W True Power and Wide range 0 to 2500 Watt True RMS measurement of ACV ACA Leakage detect AC mA de...

Page 5: ...m A current ACA 0 01 A to 10 00 A Over input mark indication Polarity Automatic switching indicates reverse polarity Zero Adjustment Automatic adjustment Sampling Time Approx 1 5 second Data Hold Free...

Page 6: ...V adapter AP 9VA Accessories USB cable USB 01 RS232 cable UPCB 02 Data Acquisition software SW U801 WIN Hard carrying case CA 08 2 2 Electrical specifications 23 5 AC DC VOLTAGE Range Range 1 0 01V to...

Page 7: ...ltage 120 AVC or Input current 1 ACA Beyond above input the resolution will still be 1 W Measuring Signals come from the top power plug input Accuracy is test under input signal is sine wave 50 60 Hz...

Page 8: ...100 0 V ACA 0 001 A resolution is valid from 0 001 A to 1 200 A ACA 0 01 A resolution is valid from 1 2 A Measuring signals come from the top power plug input power source Auto range ACV ACA accuracy...

Page 9: ...on 3 3 Record button MAX MIN 3 4 Data hold button 3 5 Power function rotary switch 3 6 ACV DCV input terminal 3 7 Load terminal 3 8 Power source terminal 3 9 Battery Cover Compartment 3 10 Stand 3 11...

Page 10: ...1 Rotate the function switch to the DCV position and Power ON the meter 2 Connect Red test lead to the V input terminal and Black test lead to COM input terminal 3 Use the test lead measurement unknow...

Page 11: ...nt power switch 6 It can read the Power Consumption value on the top LCD Display At the same time If your equipment exist current leakage It will show the leakage current value on the bottom LCD Displ...

Page 12: ...232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 11 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232...

Page 13: ...for Display ACV 50 DCV 34 K 39 38 W 47 m A 53 ACA 52 D13 When send the upper display data 1 When send the lower display data 2 D14 4 D15 Start Word RS232 FORMAT 9600 N 8 1 Baud rate 9600 Parity No par...

Page 14: ...er by screwdriver then move the batteries 3 Replace with 1 5V x 8 PCs batteries and reinstate the cover 8 THE ADDRESS OF AFTER SERVICE CENTER 11 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3...

Reviews: