Contents
NOTE
Data contained herein may differ in details from the equipment delivered. We reserve the right to make alterations without
notice.
5
Commissioning
............................................................................................................................................................................................... 18
5.1
Installation .......................................................................................................................................................................................... 18
5.2
Connection .......................................................................................................................................................................................... 18
5.3
Easy setting of operating modes with Normset ...................................................................................................................... 19
5.4
Function tests; operational settings ............................................................................................................................................ 19
5.5
Tap position indication .................................................................................................................................................................... 20
6
Parallel operation
.......................................................................................................................................................................................... 21
6.1
Parallel operation
with "Minimum Circulating Reactive Current Method“ .................................................................... 22
6.1.1
System configuration, settings ....................................................................................................................................... 22
6.1.2
Setting the interference variable (CIRCUL. REAC. CURR. STABILITY) .................................................................. 22
6.1.3
Setting the bandwidth for circulating reactive current (blocking threshold) ................................................. 22
6.1.4
Function tests, commissioning ........................................................................................................................................ 23
6.1.4.1
Preliminary settings .......................................................................................................................................... 23
6.1.4.2
Setting the interference variable (CIRCUL. REAC. CURR. STABILITY) ................................................ 23
6.1.4.3
Setting the circulating reactive current monitoring
(CIRCUL. REAC. CURR. MON. BANDWIDTH) ............................................................................................... 23
6.2
Parallel operation according to synchronized tap-change operation Master/ Follower ............................................ 23
6.2.1
System configuration, settings, transfer of
the on-load tap-changer setting ................................................ 24
6.2.1.1
Setting the tapping position range ............................................................................................................. 24
6.2.1.2
Selecting the Master/Follower operation .................................................................................................. 25
6.2.2
Function tests, commissioning and preliminary settings ........................................................................................ 25
6.3
Parallel operation with existing parallel control unit SKB 30 based on
"minimum circulating reactive current" .................................................................................................................................... 25
6.4
Disturbances during parallel operation ...................................................................................................................................... 25
7
Appendix
........................................................................................................................................................................................................... 27
NOTE
A "PARAM?" message appearing in the first line of the display indicates a negative result of the parameter verification that may
be caused by interference above the permissible electromagnetic compatibility limit (see information on standardisation and
verification in section 2). In this case, voltage regulation is blocked for safety reasons.
Check the settings in order to clear the blocking. Press and hold the "SELECT" key and press the "
" or "
" key for displaying
the current settings (see section 3.2.1). Voltage regulation is reinstated once invalid settings have been corrected while cycling
through the menu. The status LEDs and status relays are activated, and the display shows the current measurement readings.