12 Technical data
107
BA6820378-03 EN
Options
Offshore
Connection box in accordance with the require-
ments of DIN EN ISO 12944-9 with corrosion
class CX;
Offshore flange version
Cable gland stainless-steel version (grade
1.4404)
Insect grille
See dimensional drawings in attachment 7
SED 6356099
Cable protection
Protects the cable from damage such as ani-
mal bites, designed as a spiral coiled hose
(stainless steel, suitable for offshore applica-
tions); refer to dimensional drawings in attach-
ment 4 SED 6600056 and attachment 5 SED
6600296
Filter heater
HT version: With heated stainless-steel filter;
recommended for cold regions with an ambient
temperature that is continuously below 0°C for
more than 20 days in order to guarantee
proper functioning
Switching point < 5°C (switch on)
Lateral mounting
See dimensional drawings in attachment 2
SED 6356077 and attachment 3 SED 6367297
Protective grate
See dimensional drawings in attachment 7
SED 6356099
Data logger software
For the evaluation of the MTRAB data
RS485 interface
For connection to a SCADA system
Overvoltage protection
For protection against overvoltages
Summary of Contents for MESSKO MTRAB
Page 1: ...Dehydrating breather MESSKO MTRAB Operating instructions BA6820378 03 EN Version 2 5 ...
Page 19: ...3 Product description 19 BA6820378 03 EN 3 2 Design versions Figure 1 Design ...
Page 114: ......
Page 121: ......
Page 122: ......
Page 123: ......