Accessory/Options

Part No.

Impact on Steam Generator

AromaSteam Fragrance Pump

MSAROMA

Plumbing line 6 ft. cable length

iSteam3 Control

iSteam3-BK

Limited by 30 ft. or 60 ft. cable

iSteam3-WH

AirTempo Control

Designer Code*

Consider wireless range, maximum range is 60 ft.

Designer Code*

iTempo Control

MSIT

Designer Code*

Limited by 30 ft. or 60 ft. cable

MSITEMPOSQ

+ Designer Code*

iTempo/Plus Control

MSIT

Designer Code*

Limited by 30 ft. or 60 ft. cable

MSITPLUSSQ

+ Designer Code*

Linear Steam Head

104216, 104217

Plumbing

Home Wizard

HOMEWIZARD-BLK

Limited by 30 ft. or 60 ft. cable

HOMEWIZARD-WH

ChromaSteam3

MSCHROMA3-BK

Limited by 60 ft. cable

Color Lighting

MSCHROMA3-WH
CHROMA3DUOBK
CHROMA3DUOBK
CHROMA3DUOWH

AudioSteam Music Experience

MSAS3

Limited by 60 ft. cable

SteamLinx App Module

STEAMLINX

Limited by 60 ft. wireless range between modules

* Designer Codes:

PC= Polished Chrome PN = Polished Nickel BN=Brushed Nickel PB= Polished Brass BB=Brushed Bronze
ORB=Oil Rubbed Bronze SB=Satin Brass MB=Matte Black WH=White Glass Fascia BK=Black Glass Fascia RAW=Raw

Summary of Contents for MX4E

Page 1: ...m Feel Good Inc ____________________ IMPORTANT Leave this material with the homeowner ____________________ Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models...

Page 2: ...Wiring Diagrams 14 Connecting Multiple Generators 15 POST INSTALLATION INFORMATION Generator and Start Up Checkout 15 Troubleshooting 16 17 OPTIONS ACCESSORIES Controls 18 AutoFlush 19 20 Condensation...

Page 3: ...fore using a steam bath Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or product damage This highlights information that is especially relevan...

Page 4: ...EATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL DRUGS OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS 5 DO NOT CONTACT STEAMHEAD OR STEAM AT THE STEAMHEAD REDUCE THE RISK OF SLIPPING...

Page 5: ...lity can affect steam generator efficiency and or result in steam generator damage Water contains impurities in solution and suspension These impurities con centrate in the generator The concentration...

Page 6: ...ration and remain hot after shut down for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and steamhead locations that can come in contact with...

Page 7: ...mensions Wt lbs MX4E 20 84 3 483 678 2 7 251 8 L x 203 4 H x 77 8 D 67 MX5E 24 100 1 679 822 3 2 251 8 L x 203 4 H x 77 8 D 67 MX6E 30 125 2 0 823 964 4 0 251 8 L x 203 4 H x 77 8 D 67 Applies to 1 8...

Page 8: ...Applies to 1 2 1 Do not install MAX series inside a vanity or other small enclosed spaces Do not install under the steam room bench Installing the MAX steam generator in a small enclosed space may res...

Page 9: ...TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS Connecting power directly to the elements will result in a dry fire and result in elevated tempera tures and a fire hazard MX...

Page 10: ...nerators 12 ft All Models 103917 Tandem Cable for up to 5 generators 30 ft All Models 103990 60 Cable for iTempo AirTempo Control 60 ft All Models 104117 30 Cable for iSteam AirTempo iTempo 30 ft All...

Page 11: ...t a designated location on the steam piping See the MrSteam AromaSteam Operation and Instruction Manual PN 100402 for installation information before the steam piping is installed at the technical dow...

Page 12: ...g with fiberglass pipe insulation or similar insulation rated 212 F or higher 8 Pitch steam piping 1 4 per foot towards steamhead or steam generator to avoid valleys and trapping of conden sate Runnin...

Page 13: ...any material product or surface from deteriorating do not locate the steamheads where direct steam emission would come in direct contact with non heat or moisture resisitant products or materials 4 To...

Page 14: ...or illustrative purposes only ELECTRICAL Applies to 1 9 1 Never use damaged equipment doing so may result in an inoperative or hazardous installation 2 All electrical wiring installation to be perform...

Page 15: ...E 208 240 VOLT WIRING DIAGRAM MODELS MX4E MX5E MX6E mr steam Installation Operation Maintenance Manual __________________________________________________________________________ CONTACTOR EXPRESS STEA...

Page 16: ...N Secondary Unit Primary Unit Connector wires will be reverse color on secondary generator Power Supply Water Feed Line Applies to 1 2 1 Install each unit as in a single installation Install the gener...

Page 17: ...erify that the green light on the Circuit Board is ON Step 5 Push the white Force On test button on the circuit board see page 17 to run the generator for a 10 minute test cycle Make sure the steam ro...

Page 18: ...e to be performed by qualified and licensed electricians and plumbers only Installation or service by unqualified persons or failure to use MrSteam parts may result in property damage or in a personal...

Page 19: ...id unintentional steambath operation do not locate the control where other controls accessories shower heads valves body sprays or similar within the shower could cause confusion or interfere with the...

Page 20: ...y location where accidental contact with drain water may occur In the event of a power failure the AutoFlush valve will open and may discharge boiling water causing a scalding hazard 4 Do not connect...

Page 21: ...to condensation pan and cause a leak and property damage 7 See pages 10 11 for complete drain line and plumbing instructions 10 The steam generator drains by gravity Plumb all drain lines accordingly...

Page 22: ...t cable length iSteam3 Control iSteam3 BK Limited by 30 ft or 60 ft cable iSteam3 WH AirTempo Control AIRTBK Designer Code Consider wireless range maximum range is 60 ft AIRTWH Designer Code iTempo Co...

Page 23: ...injury or death if improperly used 8 Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyp...

Page 24: ...ng a suitable and safe steam room 17 MrSteam steam generators are intended to be operated with MrSteam controls and accessories only and are to be installed strictly in accordance with the specific in...

Page 25: ...n before using aromatherapy Applies to 1 6 1 Use essential oils with caution Essential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are poten...

Page 26: ...410 S La Cienega Blvd Inglewood CA 90301 TEL 1 800 72 STEAM 2020 Sussman Automatic Corporation I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package...

Reviews: