background image

18

Applies to 1-7

1. Install the iSteam, AirTempo, iTempo or iTempo/Plus

controls according to installation instructions, pro-
vided with the controls. Failure to install according
to instructions will result in an inoperative control or
hazardous overheating or inadequate heating of the
steam room.

2. The iSteam

®

, AirTempo

®

, iTempo

®

and iTempoPlus

controls are designed to be installed inside or out-
side the steam room as a matter of personal prefer-
ence. If an iSteam, AirTempo, iTempo or
iTempoPlus control is installed outside the steam
room a Remote Temperature Probe (PN MSTS)
must be installed inside the steam room per instal-
lation instructions supplied with the Remote
Temperature Probe. Failure to install according to
instructions will result in an inoperative control and
overheating of the steam room.

3. Do not route iSteam, AirTempo, iTempo/Plus,

iTempo, HomeWizard or iGenie control wiring inside
conduit together with power lines or close to hot
water or steam piping. Doing so may result in an inop-
erative or hazardous installation.

4. Do not alter or modify any MrSteam product. Doing

so may result in an inoperative or hazardous installa-
tion and will void the UL listing and warranty.

5. If the control is installed inside the steam room the

control must be located 4 - 5 feet above the floor
near the bather seating area. Failure to install the
control 4-5 feet above the floor may result in an
operative control and over or under heating of the
steam room.

6. The control features an integral temperature sensor.

Locate the control in a location representative of
the desired steam bathing temperatures. Do not
locate the control above or near the steamhead or
direct steam emissions. Locating the control near
the steamhead will not allow the temperature sen-
sor to record the correct toom temperature and
result in inadequate heating.

7. Locate the control on a vertical wall.

Applies to 8-10

8. To avoid unintentional steambath operation, do not locate the

control where other controls, accessories, shower heads, valves,
body sprays or similar within the shower could cause confusion or
interfere with the MrSteam control’s intended use and function.

9. Do not use any iSteam

®

, AirTempo

®

, iTempo/Plus

®

, iTempo

®

,

HomeWizard

®

or iGenie

®

controls without reading and understand-

ing its own manual and the MrSteam steam generator Installation
and Operation Manual. Failure to read and understand these
instructions may result in an inoperative or hazardous installation.

10. Do not operate iSteam, AirTempo,iTempo/Plus, iTempo,

HomeWizard or iGenie controls with other than a MrSteam iSteam,
AirTempo, or iTempo compatible steam generator. MrSteam resi-
dential steam generators with serial numbers lower than 900000, or
any other brand of steam generator are not to be operated with
iTempo controls. Doing so may result in an inoperative or haz-
ardous installation. If iSteam is used with a generator having serial
number less than 1174000, contact MrSteam technical support for
an upgraded PC board.

Applies to 11-14

11. Turn power to the steam generator OFF before connecting any

control to the generator. Failure to turn the power off will result in
an inoperable control.

12. Discontinue use of the steam generator or control if the steam

generator is damaged or otherwise not functioning properly.
Operating a damaged steam generator may result in an inopera-
tive or hazardous installation.

13. The control cable should be run in a dedicated 1” conduit to

facilitate installation and service.

14. The standard control cable length is 30 feet. Ensure that the

control and/or steam generator are located accordingly.
Contact a MrSteam technical service representative if a 60 foot
cable is required. Excess control cable should be neatly coiled
and twisted into a figure 8.

CONTROL INSTALLATION

Refer to Installation Instructions for the specific control

A S S E S S O R I E S

30' Cable

60' Cable

Control

(standard)

(optional)

iSteam

104117-30

104117-60

iTempoPlus 104117-30

103990-60

iTempo

104117-30

103990-60

AirTempo

104117-30

103990-60

Summary of Contents for MX4E

Page 1: ...m Feel Good Inc ____________________ IMPORTANT Leave this material with the homeowner ____________________ Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models...

Page 2: ...Wiring Diagrams 14 Connecting Multiple Generators 15 POST INSTALLATION INFORMATION Generator and Start Up Checkout 15 Troubleshooting 16 17 OPTIONS ACCESSORIES Controls 18 AutoFlush 19 20 Condensation...

Page 3: ...fore using a steam bath Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or product damage This highlights information that is especially relevan...

Page 4: ...EATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL DRUGS OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS 5 DO NOT CONTACT STEAMHEAD OR STEAM AT THE STEAMHEAD REDUCE THE RISK OF SLIPPING...

Page 5: ...lity can affect steam generator efficiency and or result in steam generator damage Water contains impurities in solution and suspension These impurities con centrate in the generator The concentration...

Page 6: ...ration and remain hot after shut down for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and steamhead locations that can come in contact with...

Page 7: ...mensions Wt lbs MX4E 20 84 3 483 678 2 7 251 8 L x 203 4 H x 77 8 D 67 MX5E 24 100 1 679 822 3 2 251 8 L x 203 4 H x 77 8 D 67 MX6E 30 125 2 0 823 964 4 0 251 8 L x 203 4 H x 77 8 D 67 Applies to 1 8...

Page 8: ...Applies to 1 2 1 Do not install MAX series inside a vanity or other small enclosed spaces Do not install under the steam room bench Installing the MAX steam generator in a small enclosed space may res...

Page 9: ...TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS Connecting power directly to the elements will result in a dry fire and result in elevated tempera tures and a fire hazard MX...

Page 10: ...nerators 12 ft All Models 103917 Tandem Cable for up to 5 generators 30 ft All Models 103990 60 Cable for iTempo AirTempo Control 60 ft All Models 104117 30 Cable for iSteam AirTempo iTempo 30 ft All...

Page 11: ...t a designated location on the steam piping See the MrSteam AromaSteam Operation and Instruction Manual PN 100402 for installation information before the steam piping is installed at the technical dow...

Page 12: ...g with fiberglass pipe insulation or similar insulation rated 212 F or higher 8 Pitch steam piping 1 4 per foot towards steamhead or steam generator to avoid valleys and trapping of conden sate Runnin...

Page 13: ...any material product or surface from deteriorating do not locate the steamheads where direct steam emission would come in direct contact with non heat or moisture resisitant products or materials 4 To...

Page 14: ...or illustrative purposes only ELECTRICAL Applies to 1 9 1 Never use damaged equipment doing so may result in an inoperative or hazardous installation 2 All electrical wiring installation to be perform...

Page 15: ...E 208 240 VOLT WIRING DIAGRAM MODELS MX4E MX5E MX6E mr steam Installation Operation Maintenance Manual __________________________________________________________________________ CONTACTOR EXPRESS STEA...

Page 16: ...N Secondary Unit Primary Unit Connector wires will be reverse color on secondary generator Power Supply Water Feed Line Applies to 1 2 1 Install each unit as in a single installation Install the gener...

Page 17: ...erify that the green light on the Circuit Board is ON Step 5 Push the white Force On test button on the circuit board see page 17 to run the generator for a 10 minute test cycle Make sure the steam ro...

Page 18: ...e to be performed by qualified and licensed electricians and plumbers only Installation or service by unqualified persons or failure to use MrSteam parts may result in property damage or in a personal...

Page 19: ...id unintentional steambath operation do not locate the control where other controls accessories shower heads valves body sprays or similar within the shower could cause confusion or interfere with the...

Page 20: ...y location where accidental contact with drain water may occur In the event of a power failure the AutoFlush valve will open and may discharge boiling water causing a scalding hazard 4 Do not connect...

Page 21: ...to condensation pan and cause a leak and property damage 7 See pages 10 11 for complete drain line and plumbing instructions 10 The steam generator drains by gravity Plumb all drain lines accordingly...

Page 22: ...t cable length iSteam3 Control iSteam3 BK Limited by 30 ft or 60 ft cable iSteam3 WH AirTempo Control AIRTBK Designer Code Consider wireless range maximum range is 60 ft AIRTWH Designer Code iTempo Co...

Page 23: ...injury or death if improperly used 8 Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyp...

Page 24: ...ng a suitable and safe steam room 17 MrSteam steam generators are intended to be operated with MrSteam controls and accessories only and are to be installed strictly in accordance with the specific in...

Page 25: ...n before using aromatherapy Applies to 1 6 1 Use essential oils with caution Essential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are poten...

Page 26: ...410 S La Cienega Blvd Inglewood CA 90301 TEL 1 800 72 STEAM 2020 Sussman Automatic Corporation I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package...

Reviews: