18
Applies to 1-7
1. Install the iSteam, AirTempo, iTempo or iTempo/Plus
controls according to installation instructions, pro-
vided with the controls. Failure to install according
to instructions will result in an inoperative control or
hazardous overheating or inadequate heating of the
steam room.
2. The iSteam
®
, AirTempo
®
, iTempo
®
and iTempoPlus
controls are designed to be installed inside or out-
side the steam room as a matter of personal prefer-
ence. If an iSteam, AirTempo, iTempo or
iTempoPlus control is installed outside the steam
room a Remote Temperature Probe (PN MSTS)
must be installed inside the steam room per instal-
lation instructions supplied with the Remote
Temperature Probe. Failure to install according to
instructions will result in an inoperative control and
overheating of the steam room.
3. Do not route iSteam, AirTempo, iTempo/Plus,
iTempo, HomeWizard or iGenie control wiring inside
conduit together with power lines or close to hot
water or steam piping. Doing so may result in an inop-
erative or hazardous installation.
4. Do not alter or modify any MrSteam product. Doing
so may result in an inoperative or hazardous installa-
tion and will void the UL listing and warranty.
5. If the control is installed inside the steam room the
control must be located 4 - 5 feet above the floor
near the bather seating area. Failure to install the
control 4-5 feet above the floor may result in an
operative control and over or under heating of the
steam room.
6. The control features an integral temperature sensor.
Locate the control in a location representative of
the desired steam bathing temperatures. Do not
locate the control above or near the steamhead or
direct steam emissions. Locating the control near
the steamhead will not allow the temperature sen-
sor to record the correct toom temperature and
result in inadequate heating.
7. Locate the control on a vertical wall.
Applies to 8-10
8. To avoid unintentional steambath operation, do not locate the
control where other controls, accessories, shower heads, valves,
body sprays or similar within the shower could cause confusion or
interfere with the MrSteam control’s intended use and function.
9. Do not use any iSteam
®
, AirTempo
®
, iTempo/Plus
®
, iTempo
®
,
HomeWizard
®
or iGenie
®
controls without reading and understand-
ing its own manual and the MrSteam steam generator Installation
and Operation Manual. Failure to read and understand these
instructions may result in an inoperative or hazardous installation.
10. Do not operate iSteam, AirTempo,iTempo/Plus, iTempo,
HomeWizard or iGenie controls with other than a MrSteam iSteam,
AirTempo, or iTempo compatible steam generator. MrSteam resi-
dential steam generators with serial numbers lower than 900000, or
any other brand of steam generator are not to be operated with
iTempo controls. Doing so may result in an inoperative or haz-
ardous installation. If iSteam is used with a generator having serial
number less than 1174000, contact MrSteam technical support for
an upgraded PC board.
Applies to 11-14
11. Turn power to the steam generator OFF before connecting any
control to the generator. Failure to turn the power off will result in
an inoperable control.
12. Discontinue use of the steam generator or control if the steam
generator is damaged or otherwise not functioning properly.
Operating a damaged steam generator may result in an inopera-
tive or hazardous installation.
13. The control cable should be run in a dedicated 1” conduit to
facilitate installation and service.
14. The standard control cable length is 30 feet. Ensure that the
control and/or steam generator are located accordingly.
Contact a MrSteam technical service representative if a 60 foot
cable is required. Excess control cable should be neatly coiled
and twisted into a figure 8.
CONTROL INSTALLATION
Refer to Installation Instructions for the specific control
A S S E S S O R I E S
30' Cable
60' Cable
Control
(standard)
(optional)
iSteam
104117-30
104117-60
iTempoPlus 104117-30
103990-60
iTempo
104117-30
103990-60
AirTempo
104117-30
103990-60