mr. steam MS-150T Installation, Operation & Maintenance Manual Download Page 24

mr

.

steam

steambaths

®

tempo controls

23

Tempo

®

Operating Instructions

The Tempo Control features programmable digital temperature control,
a fixed (60) minute duration, ON/OFF and PAUSE.

ON/OFF - Diagram 1

Press the ON/OFF key to start or stop the flow of steam.
Steam will begin to flow a few minutes after the control is turned ON.
The duration required for the steamroom to reach steambathing tem-
peratures depends on the steamroom construction and steam generator
specifications. Steam may continue to flow for a short time after the
control is turned OFF.

PAUSE feature - Diagram 2

If a pause in steam flow is desired press the PAUSE key. The display will
flash while the control is in the PAUSE mode. The timer will continue
to countdown while in the PAUSE mode.

Setting the temperature - Diagram 3

The control is pre-set and will display the temperature setting of 110F
(default setting). Use the UP and DOWN keys to change the  tempera-
ture setting from 105 F to 120 F in one degree increments.
Set the steambathing temperature according to personal preference,
however it is highly recommended to begin steambathing at a low tem-
perature setting to gauge comfort and safety levels.

Timer feature

When the control is turned ON a 60 minute time duration is initiated.
The control will turn off after 60 minutes unless the control is turned
off manually.

Memory feature

If the control is turned off manually before 60 minutes then the
default temperature of 110˚F will be used the next time the control is
turned on. If the control times out at 60 minutes (not manually turned
off) then the previous user temperature setting will be used when the
steambath is used again.

DIAGRAM 1

DIAGRAM 2

DIAGRAM 3

Summary of Contents for MS-150T

Page 1: ...Residential Steambath Generator Systems Installation Operation Maintenance Manual...

Page 2: ...available at the time of publica tion Sussman Automatic Corporation reserves the right to make changes at any time without notice CAUTION WARNING states a hazard may cause serious injury or death if...

Page 3: ...ing AromaSteam Essential Oils 15 Liquid Level Control Board 16 Select Your MrSteam Model 17 Replacement Parts Diagram 18 Replacement Parts List 19 Tempo Controls General Information Care Tips 20 Safet...

Page 4: ...urfaced flooring is used provide suitable anti skid strips or equivalent to prevent user slipping and injury 4 Walls and ceilings must be constructed of water resistant non corrosive surface such as t...

Page 5: ...tate installation and disconnection of piping 11 IMPORTANT Steam line safety valve drain valve plumbing and steamheads become hot during operation and remain hot after shutdown for a period of time Pr...

Page 6: ...ts as shown in Diagram A Connect each end to the printed circuit board connector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet safety va...

Page 7: ...ad where incidental contact by bather with the steam head or direct steam emission cannot occur 1 Locate steam head 6 12 inches above floor except for Tub shower enclosures install 6 inches above tub...

Page 8: ...3 8 60 __________________________________ M 6 152 6 3 8 162 NOTES 1 M Optional AutoFlush 2 All units in inches MM 3 MS Super 4T includes 2 MS Super 1T units 4 MS Super 5T includes 2 MS Super 2T units...

Page 9: ...____________________________________________________________________ MS 225T 250 7 5 208 36 8 240 32 8 _________________________________________________________________________________________________...

Page 10: ...ENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS __________________________________________________ NOTE FOR ILLUSTRATIVE PURPOSES ONLY CONSULT WITH QUALIFIED LICENSED ELECTRICIAN FOR ELECT...

Page 11: ...NSFORMER WATER FEED SOLENOID VALVE SINGLE PHASE MS 65T MS 90T MS 150T MS 225T MS 300T MS 400T SINGLE PHASE MS SUPER 1T MS SUPER 2T MS SUPER 3T WATER FEED SOLENOID VAVLE HEATING ELEMENT CONTROL BOARD G...

Page 12: ...N 103904 through the knock outs as shown in diagram A page 5 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring Diagram MS Super...

Page 13: ...e Manual 12 Three Phase Wiring Diagram with Tempo Plus Control Installation Instructions for Models MS Super 4T MS Super 5T and MS Super 6T 1 Install each unit as in a single installation as close to...

Page 14: ...e minimal Every 2 months or more often in hard water areas the manual drain valve should be opened fully flushing out accumulated materials salts and other particles which are natural by products of b...

Page 15: ...Drain Valve valve end A and B are indicated on bottom of AutoFlush Valve DO NOT REMOVE THE DRAIN VALVE Removal may cause equipment and property damage If there is not enough room for the valve an elbo...

Page 16: ...ential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irrit...

Page 17: ...___ With TEMPO or TEMPO PLUS control ON _________________________________________________________________________________________________ HTR Room temperature status indicator LED is ON when control i...

Page 18: ...ads MS SUPER 5T includes two MS SUPER 2T steam generators and one TEMPO PLUS Control and two matching AromaSteam steam heads MS SUPER 6T includes two MS SUPER 3 steam generators and one TEMPO PLUS Con...

Page 19: ...Valve Data Plate AutoFlush Valve optional Stainless Steel Tank Heating Element Access Cover Liquid Level Probe Plug and Play Connection see page 14 Power Block Power Supply Knock Out Water Feed Sussm...

Page 20: ...pole MS Super 1T Super 6T 100471 2 Probe Assembly All models 99096 MS Heating Element Gasket All models MS 103938 Acrylic Shield All Models 99314 Power Fuse 60A 250V MS Super 1T 6T Single phase 29041...

Page 21: ...will result in an inoperative control and overheating of the steamroom _________________________________________________________________________________________________________ Do not route Tempo Plu...

Page 22: ...l and or steam gener ator are located accordingly Contact a MrSteam technical service representa tive if a longer cable is required If the control is installed outside the steam room a Remote Temperat...

Page 23: ...Step 6 Run a bead of silicone provided as shown to the C shaped groove as shown in Diagram 4 IMPORTANT Do not apply excessive amounts of sili cone Do not apply silicone to any other parts of the con t...

Page 24: ...e PAUSE mode Setting the temperature Diagram 3 The control is pre set and will display the temperature setting of 110F default setting Use the UP and DOWN keys to change the tempera ture setting from...

Page 25: ...ly recommended to begin steambathing at a shorter duration to gauge comfort and safety levels The control will turn off when the relaxation period times out Setting the temperature Press TEMP key to s...

Page 26: ...eet It is for use inside the steam room and requires a direct line of sight with the TEMPO PLUS Control The TEMPO REMOTE does not operate with the TEMPO Control To operate the TEMPO REMOTE simply poin...

Page 27: ...ey NOTE The Timer continues to count down while in the PAUSE mode 2 Press PAUSE key a second time to resume the flow of steam Setting the Program Values To Set PROG 1 and PROG 2 1 Press PROG 1 or PROG...

Page 28: ...lash twice indicating that programmed codes are still in memory If LED indicator flashes 3 times it means that programmed code settings have been erased reenter the code per instructions on page 25 In...

Page 29: ...o not oversize or undersize the hole Route the cable from the wall to the steam generator Do not strain staple pinch or otherwise damage the control cable STEP 3 Diagram 3 Remove and discard the peel...

Page 30: ...rom the steam head 4 Not exposed to direct steam emission The probe has an integral 30 cable Insure that the probe and or steam generator are located accordingly Contact a MrSteam technical service re...

Page 31: ...cable and bulb into hole as required to leave minimum 1 4 maximum 1 2 of the bulb exposed as shown below Insure a minimum of 1 4 of the temperature bulb is exposed to the air Failure to do so may res...

Page 32: ...sman Automatic Corporation info mrsteam com www mrsteam com 43 20 34th Street Long Island City NY 11101 Tel 1 800 76 STEAM Fax 718 472 3256 Western 9410 S La Cienega Blvd Inglewood CA 90301 1 800 72 S...