mr. steam MS-150T Installation, Operation & Maintenance Manual Download Page 20

mr

.

steam

steambaths

®

Installation, Operation & Maintenance Manual

19

Replacement Parts List

_______________________________________________________________________

Part No.

Description

Product

_______________________________________________________________________
99178

Drain Valve

MS Super-1T – Super-6T

99178MS

Drain Valve

MS 65T – MS 400T

99297

Safety Valve 15PSI

All models

100479

Water Feed Solenoid Valve w/filter

All models

100477-1

Transformer 24VAC

All models

103899

Liquid Level Control Board

All models

103904

Tandem Cable for 2 generators (12 ft.)

All models

103917

Tandem Cable for up to 5 generators (30 ft.)

All Models

103905

Cable for Tempo Control (30 ft.)

All models

103922

Cable for Tempo Control (60 ft.)

All models

MSTS

Remote Temperature Probe

All models

100476-2

Contactor 50A 2-pole

MS-65T-400T, Single phase

99012

Contactor 50A 3-pole

All 3-Phase models

103453

Contactor 50A 4-pole

MS Super-1T – Super-6T 

100471-2

Probe Assembly

All models

99096 MS

Heating Element Gasket

All models

MS-103938  

Acrylic Shield  

All Models

99314

Power Fuse 60A 250V

MS-Super 1T–6T Single phase

29041BMS

Heating Element 4.5 KW 208V

MS 65T

29041CMS

Heating Element 4.5 KW 240V

MS 65T

29051BMS

Heating Element 5  KW 208V

MS 90T

29051CMS

Heating Element 5  KW 240V

MS 90T

29061BMS

Heating Element 6  KW 208V

MS 150T

29061CMS

Heating Element 6  KW 240V

MS 150T

29071BMS

Heating Element 7.5 KW 208V

MS 225T

29071CMS

Heating Element 7.5 KW 240V

MS 225T

29081BMS

Heating Element 8.5 KW 208V

MS 300T

29081CMS

Heating Element 8.5 KW 240V

MS 300T

29091BMS

Heating Element 9  KW 208V

MS 400T

29091CMS

Heating Element 9  KW 240V

MS 400T

29101BMS

Heating Element 10 KW 208V

MS SUPER-1T & MS Super-4T

29101CMS

Heating Element 10 KW 240V

MS SUPER-1T & MS Super-4T

29121BMS

Heating Element 12 KW 208V

MS SUPER-2T & MS Super-5T

29121CMS

Heating Element 12 KW 240V

MS SUPER-2T & MS Super-5T

29151BMS

Heating Element 15 KW 208V

MS SUPER-3T & MS Super-6T

29151CMS

Heating Element 15 KW 240V

MS SUPER-3T & MS Super-6T

Summary of Contents for MS-150T

Page 1: ...Residential Steambath Generator Systems Installation Operation Maintenance Manual...

Page 2: ...available at the time of publica tion Sussman Automatic Corporation reserves the right to make changes at any time without notice CAUTION WARNING states a hazard may cause serious injury or death if...

Page 3: ...ing AromaSteam Essential Oils 15 Liquid Level Control Board 16 Select Your MrSteam Model 17 Replacement Parts Diagram 18 Replacement Parts List 19 Tempo Controls General Information Care Tips 20 Safet...

Page 4: ...urfaced flooring is used provide suitable anti skid strips or equivalent to prevent user slipping and injury 4 Walls and ceilings must be constructed of water resistant non corrosive surface such as t...

Page 5: ...tate installation and disconnection of piping 11 IMPORTANT Steam line safety valve drain valve plumbing and steamheads become hot during operation and remain hot after shutdown for a period of time Pr...

Page 6: ...ts as shown in Diagram A Connect each end to the printed circuit board connector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet safety va...

Page 7: ...ad where incidental contact by bather with the steam head or direct steam emission cannot occur 1 Locate steam head 6 12 inches above floor except for Tub shower enclosures install 6 inches above tub...

Page 8: ...3 8 60 __________________________________ M 6 152 6 3 8 162 NOTES 1 M Optional AutoFlush 2 All units in inches MM 3 MS Super 4T includes 2 MS Super 1T units 4 MS Super 5T includes 2 MS Super 2T units...

Page 9: ...____________________________________________________________________ MS 225T 250 7 5 208 36 8 240 32 8 _________________________________________________________________________________________________...

Page 10: ...ENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS __________________________________________________ NOTE FOR ILLUSTRATIVE PURPOSES ONLY CONSULT WITH QUALIFIED LICENSED ELECTRICIAN FOR ELECT...

Page 11: ...NSFORMER WATER FEED SOLENOID VALVE SINGLE PHASE MS 65T MS 90T MS 150T MS 225T MS 300T MS 400T SINGLE PHASE MS SUPER 1T MS SUPER 2T MS SUPER 3T WATER FEED SOLENOID VAVLE HEATING ELEMENT CONTROL BOARD G...

Page 12: ...N 103904 through the knock outs as shown in diagram A page 5 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring Diagram MS Super...

Page 13: ...e Manual 12 Three Phase Wiring Diagram with Tempo Plus Control Installation Instructions for Models MS Super 4T MS Super 5T and MS Super 6T 1 Install each unit as in a single installation as close to...

Page 14: ...e minimal Every 2 months or more often in hard water areas the manual drain valve should be opened fully flushing out accumulated materials salts and other particles which are natural by products of b...

Page 15: ...Drain Valve valve end A and B are indicated on bottom of AutoFlush Valve DO NOT REMOVE THE DRAIN VALVE Removal may cause equipment and property damage If there is not enough room for the valve an elbo...

Page 16: ...ential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irrit...

Page 17: ...___ With TEMPO or TEMPO PLUS control ON _________________________________________________________________________________________________ HTR Room temperature status indicator LED is ON when control i...

Page 18: ...ads MS SUPER 5T includes two MS SUPER 2T steam generators and one TEMPO PLUS Control and two matching AromaSteam steam heads MS SUPER 6T includes two MS SUPER 3 steam generators and one TEMPO PLUS Con...

Page 19: ...Valve Data Plate AutoFlush Valve optional Stainless Steel Tank Heating Element Access Cover Liquid Level Probe Plug and Play Connection see page 14 Power Block Power Supply Knock Out Water Feed Sussm...

Page 20: ...pole MS Super 1T Super 6T 100471 2 Probe Assembly All models 99096 MS Heating Element Gasket All models MS 103938 Acrylic Shield All Models 99314 Power Fuse 60A 250V MS Super 1T 6T Single phase 29041...

Page 21: ...will result in an inoperative control and overheating of the steamroom _________________________________________________________________________________________________________ Do not route Tempo Plu...

Page 22: ...l and or steam gener ator are located accordingly Contact a MrSteam technical service representa tive if a longer cable is required If the control is installed outside the steam room a Remote Temperat...

Page 23: ...Step 6 Run a bead of silicone provided as shown to the C shaped groove as shown in Diagram 4 IMPORTANT Do not apply excessive amounts of sili cone Do not apply silicone to any other parts of the con t...

Page 24: ...e PAUSE mode Setting the temperature Diagram 3 The control is pre set and will display the temperature setting of 110F default setting Use the UP and DOWN keys to change the tempera ture setting from...

Page 25: ...ly recommended to begin steambathing at a shorter duration to gauge comfort and safety levels The control will turn off when the relaxation period times out Setting the temperature Press TEMP key to s...

Page 26: ...eet It is for use inside the steam room and requires a direct line of sight with the TEMPO PLUS Control The TEMPO REMOTE does not operate with the TEMPO Control To operate the TEMPO REMOTE simply poin...

Page 27: ...ey NOTE The Timer continues to count down while in the PAUSE mode 2 Press PAUSE key a second time to resume the flow of steam Setting the Program Values To Set PROG 1 and PROG 2 1 Press PROG 1 or PROG...

Page 28: ...lash twice indicating that programmed codes are still in memory If LED indicator flashes 3 times it means that programmed code settings have been erased reenter the code per instructions on page 25 In...

Page 29: ...o not oversize or undersize the hole Route the cable from the wall to the steam generator Do not strain staple pinch or otherwise damage the control cable STEP 3 Diagram 3 Remove and discard the peel...

Page 30: ...rom the steam head 4 Not exposed to direct steam emission The probe has an integral 30 cable Insure that the probe and or steam generator are located accordingly Contact a MrSteam technical service re...

Page 31: ...cable and bulb into hole as required to leave minimum 1 4 maximum 1 2 of the bulb exposed as shown below Insure a minimum of 1 4 of the temperature bulb is exposed to the air Failure to do so may res...

Page 32: ...sman Automatic Corporation info mrsteam com www mrsteam com 43 20 34th Street Long Island City NY 11101 Tel 1 800 76 STEAM Fax 718 472 3256 Western 9410 S La Cienega Blvd Inglewood CA 90301 1 800 72 S...

Reviews: