SUCTION TUBE ASSEMBLY
For your convenience the suction tube assembly is provided
preassembled. If additional tubing is needed please
contact MrSteam Technical service at 1-800-767-8326 or
1-800-727-8326.
Installation of Suction Tube to the Pump
1. Insert the suction tube through the pump tightening nut
and collar and firmly push the tube onto the tube holder.
2. Screw the suction tube tightening nut to the
suction side of the pump.
IMPORTANT NOTE:
HAND-TIGHTEN ONLY.
Installation of Suction Tube into the
Fragrance Container
1. Locate the “container cap” with the hole included with
the bottle of fragrance.
2. Insert the suction tube through the hole in the
container cap.
3. Remove the foot valve cap and insert the suction tube
through the cap. Push the suction tube onto the foot
valve. Tighten the cap onto the foot valve.
{°Ê1ÃVÀiÜÊÌ iÊV>«ÊvÀÊÌ iÊvÀ>}À>ViÊVÌ>iÀÊ>`Ê`ÃV>À`°
5. Screw the cap onto the fragrance container.
6. Make sure the Foot Valve rests on the bottom of the
fragrance container.
IMPORTANT NOTE:
To prevent connection from leaking,
insert tubing holder completely into tubing until it reaches
the bottom. Lubricate the ID of the tubing as required with
soap to facilitate insertion.
IMPORTANT NOTE:
To prevent damage do not use tools to
tighten the nut.
Suction
Tube
Assembly
Tube Holder
Collar
Pump Tightening Nut
Suction Tube
Fragrance
Container
Cap with Hole
Collar
Tube Holder
Foot Valve
Fragrance
Container
Caddy
Pump
I N S T A L L E R S E C T I O N
AromaSteam
Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
9