Box Contents

2

Shipping Hose

TABLE OF CONTENTS

Box Contents

. . . . . . . . . . . . . . . . . 2

Assembly and Installation

General . . . . . . . . . . . . . . . . . . . . . 3

Pump Assembly . . . . . . . . . . . . . . . . . 4

Installation of Hoses. . . . . . . . . . . . . . . 4

System Schematic . . . . . . . . . . . . . . . . 5

Electrical Wiring . . . . . . . . . . . . . . . . . 6

Assembly Diagram . . . . . . . . . . . . . . . . 7

Start-up

Initial Priming of Metering Pump  . . . . . . . 8

Filling the Pressure Hose . . . . . . . . . . . . 8

Programming Table . . . . . . . . . . . . . . . 9

Maintenance

Maintenance of Metering Pump, 

Suction Valve, and Pressure Valve . . . . . . . 10

Troubleshooting

. . . . . . . . . . . . . . . 11

Technical Information

. . . . . . . . . . 11

Spare Parts

. . . . . . . . . . . . . . . . . . 11

Warranty

. . . . . . . . . . . . . . . . . . . . 12

A Division of Sussman-Automatic Corporation  

43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500  • 1-800-767- 8326  • Fax: (718) 472-3256 • www.mrsteam.com

Western Regional Offices  

9410 S. La Cienega Blvd., Inglewood CA 90301 • 1-800 72 STEAM (1-800 727-8326) • Fax: (310) 216-2944

PUR 100402 - 01/06

NOTE:

Sussman-Automatic strongly recommends that this warning sign

(supplied) be posted in a conspicuous location near the steam room.

Do not use with water soluble fragrance or fragrance containing 
emulsifiers or aldehydes. AromaStean pump damage may result.
MrSteam oils are approved for operation with this pump.

The use of any oils other than MrSteam oils may introduce excessive
concentration of oil into the steam room, resulting in a health hazard.

WARNING

!

WARNING

!

signals a situation where minor injury or product
dam-age may occur if you do not follow instructions.

IMPORTANT NOTE:

THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY
RELEVANT TO A PROBLEM-FREE INSTALLATION.

IMPORTANT NOTE:

As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of
this AromaSteam. These are two types of potential hazards that may occur during this installation and operation:

states a hazard which may cause serious injury
or death if precautions are not followed.

Fragrance Metering Pump 
for Residential Steam Rooms

This room is equipped with an aromatic oil dispensing system.

Leave the room immediately if you have any adverse or 
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.

MrSteam

®

Commercial Steam Generators

Sussman-Automatic Corp. 43-20 34th Street , Long Island City  NY 11101 
1 800 76 STEAM  •  www.mrsteam.com

WARNING

!

Listed Oil Delivery

Pump 24VW

mr.steam

aromasteam

®

operation and installation instructions

_________________________________________________

WARNING

!

CAUTION 

!

AromaSteam System

6 ft. Pressure Hose

2 ft. Suction Hose with Filter

& Bracket Assembly
(with integrated 6 ft. power cord,
8 ft. request cable and 3 ft. demand cable)

1/2 inch NPT Atomizing Nozzle

Injector with Injection Hose

Scent Container Cap

Demand Button

(with integral 30 ft. cable)

Installation & Operation Manual

with Peel-off Warning Label

AromaSteam IOM 08:AromaSteam 05.IOM  6/16/08  10:24 AM  Page 2

Summary of Contents for eTempo Plus

Page 1: ...or fiberglass rooms Material Safety Data Sheet MSDS available upon request WARNING WARNING WARNING WARNING signals a situation where minor injury or product damage may occur if you do not follow instr...

Page 2: ...ARNING WARNING signals a situation where minor injury or product dam age may occur if you do not follow instructions IMPORTANT NOTE THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY RELEVANT TO A PROBLEM...

Page 3: ...tem is 1 5 ft If this minimum distance of 1 5 ft cannot be maintained install a radiation plate or heat insulation between the heat source and AromaSteam system Ambient temperature at and around the A...

Page 4: ...iner and discard 3 Insert the suction hose with the open end from below through the hole in the container cap see Fig 3 4 Insert the filter into the scent container so that the filter rests on the bot...

Page 5: ...am Head 90 T Atomizer Nozzle Pressure Hose Suction Hose Scent Container AromaSteam Demand Button Mounting Bracket AromaSteam System Steam Line Pump Line Cord 120V grounded receptacle required Tempo Te...

Page 6: ...on the request cable NOTE When using generators hooked up in tandem the AromaSteam steam system should be connected to the contactor on the primary generator The atomizing nozzle should be connected...

Page 7: ...e generator is steaming the pump will inject oil into the steam line at preset time intervals 3 If the generator is not steaming no oil will be pumped Note After the generator has been turned off the...

Page 8: ...hose or the pump head To eliminate air bubbles see Priming Pump 4 Check valves for contamination Clean valves if necessary 5 Check filter in container for contamination Rinse filter under clean water...

Reviews: