background image

Mr. Heater, Inc.| Kerosene Forced Air Heater

Operating Instructions and Owner’s Manual

5

Problem:

 

Flame extends beyond the end of the heater.

Adjustment:

 Pump pressure is too high. 

 

 

Turn adjustment screw counter clockwise to  

 

 

decrease pump pressure.

DAILY SCHEDULE

1.  GENERAL. Make general visual inspection of heater for loose 

or damaged parts. Check nuts and bolts to insure against 
looseness caused by vibration or rough handling. Damaged 
parts should be repaired or replaced before using heater 
again. Check heater operation to be sure it is operating 
normally (See “Servicing” section for description of normal 
operation).

2.  FILTERS. Dirty air or fuel filters will cause an imbalance in 

the air-fuel mixture. The best indication that this condition 
exists is an increase in odors or difficulty getting your heater 
to ignite. This heater should never be operated without the 
filters in place. If required, clean filters as described under 
“500 Hours” and “Annual Schedules”.

500 HOUR SCHEDULE

1.  AIR INTAKE FILTER. Remove and wash the filter element 

with a mild detergent, dry thoroughly and replace. Do not 
oil the filter element. If your heater is used where there 
is considerable dust or dirt, clean as often as necessary 
(approximately every 50 hrs.).

2.  REMOVE DUST. Clean heater twice a season (more often 

under dusty conditions). Remove accumulated dust from the 
transformer, burner, motor and fan blades with compressed 
air. Wipe area clean with a clean dry cloth. Inspect area to 
insure all foreign materials are removed, especially around 
the burner and combustion area.

3.  CAD CELL. Clean the glass portion of the cad cell with a soft 

dry cloth.

4.  NOZZLE. Accumulation of dirt from fuel and carbon from 

the compressor vanes will eventually fill up the passages 
in the nozzle, resulting in reduction of fuel and air flow. 
Pressure will gradually increase giving improper fuel-air 
mixture and excess odor and smoke. If this occurs, replace 
the fuel nozzle.

5.  FUEL TANK. Clean twice a season (during frequently used 

periods, clean twice a month). Drain and flush the fuel tank 
with clean fuel oil.

ANNUAL SCHEDULE

1.  AIR OUTPUT FILTER. Remove the air output filter and tap 

the contaminated side gently on a solid object to remove 
contaminates. Compressed air or liquids should not be used 
to clean this filter. Reinstall cleaned filter in filter body in the 
same position as it was when removed. If the filter appears 
extremely dirty, replace it with a new filter of the same 
type. When replacing the filter cover, be sure the gasket is 
firmly in place and the screws in the filter cover are tight to 
prevent air leaks.

2.  FUEL FILTER. Remove the fuel filter from fuel line and direct 

compressed air through the filter in the opposite direction 
of fuel flow. Safety glasses should be worn when using 
compressed air.

3.  AIR AND FUEL LINES. If the air or fuel lines are removed 

during cleaning, be sure all connections are tight before 
operating unit.

STORAGE

Store the heater in a dry location free from fumes or dust.
At the end of each heating season, clean the heater as described 
in the MAINTENANCE section. Drain and flush the fuel tank with 
clean fuel. The manufacturer recommends completely filling the 
tank with fuel for extended storage to minimize condensation 
inside the tank.
It is recommended to only store kerosene in containers that are 
marked “KEROSENE”.

SERVICING

A hazardous condition may result if a heater is used that has been 
modified or is not functioning properly. 

When the heater is working normally:

The flame is contained within the heater.

*   The flame is essentially yellow.

There is no strong disagreeable odor, eye burning or other 
physical discomfort.

There is no smoke or soot internal or external to the heater.

There are no unplanned or unexplained shut downs of the 
heater.

Summary of Contents for PA125DKTR

Page 1: ...rmed by a qualified service agency This is an unvented portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 3 KEROSENE FORCED AIR HEATER 2018 OPERATING INSTRUCTIONS AND OWNER S MANUAL READ INSTRUCTIONS CAREFULLY Read and follow all instructions Place instructions in a safe place for future reference Do not allow...

Page 2: ...NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SU...

Page 3: ...el Factory tested for use with No 2 K kerosene No 1 or No 2 Diesel No 1 or No 2 fuel oil or JP8 Jet A fuel and these fuels may be used as well Never use gasoline biodiesel oil drained from crank cases naphtha paint thinners alcohol or any other highly flammable fuels 2 Check the heater thoroughly for damage DO NOT operate a damaged heater 3 DO NOT modify the heater or operate a heater which has be...

Page 4: ...re beyond the heater in all directions HEATER START UP 1 50DKR Plug the heater into a grounded 115V 60 Hz 1 Ø outlet 75DKTR 125DKTR 175DKTR Turn thermostat to lowest setting make sure On Off switch is Off Plug the heater into a grounded 115V 60 Hz 1 Ø outlet Turn thermostat to highest setting Start heater by pushing toggle switch to On position light signifies switch is in ON position Adjust therm...

Page 5: ...f fuel and air flow Pressure will gradually increase giving improper fuel air mixture and excess odor and smoke If this occurs replace the fuel nozzle 5 FUEL TANK Clean twice a season during frequently used periods clean twice a month Drain and flush the fuel tank with clean fuel oil ANNUAL SCHEDULE 1 AIR OUTPUT FILTER Remove the air output filter and tap the contaminated side gently on a solid ob...

Page 6: ...ng troubleshooting guide for unit status and corrective action if necessary SYMPTOM TROUBLE SHOOTING High limit switch Open Circuit 1 Make sure heater is cooled off toggle switch to OFF position wait 5 minutes and retry Sparks calling for flame but 1 Check wiring to motor per wiring schematic in manual no or slow motor operation 2 Make sure that the pressure gauge is in place and not damaged 3 Adj...

Page 7: ...MOTOR CAPACITOR CIRCUIT BOARD 18AWG YELL 18AWG YELL 18AWG RED 18AWG RED 18AWG WHT 18AWG BLK 18AWG GRN 18AWG PURPLE 18AWG PINK 18AWG PINK 1 2 3 4 5 6 18AWG PURPLE THERMOSTAT 18AWG BLUE 7 8 ELECTR0DE 18AWG GRN 17AWG BLK 9 10 RED LED 11 12 18AWG BLUE 17AWG BLK 24AWG BLK 24AWG RED 18AWG BLK 18AWG WHT CAD CELL 18AWG BLUE THERMOSTAT 18AWG PURPLE COM1 I2 I1 M2 M1 L N 18AWG PURPLE 18AWG GRN 18AWG BLK 18AW...

Page 8: ...t 19 26898 26898 26898 Receptacle 110V 20 22104 22104 22104 AC Receptacle Cover 21 26833 26833 26833 26833 Air Pump Cylinder 22 21810 21810 21810 21810 Outlet Housing 23 21812 21812 21812 21812 Inlet Housing 24 22257 22257 Burner Head Ass y 25 F221887 F221887 F221887 F221887 Kit Filter 26 21814 21814 21814 21814 Outlet Filter 27 21815 21815 21815 21815 Inlet Filter 28 F266842 F266842 F266842 F2668...

Page 9: ...ons and Owner s Manual 9 1 2 3 4 5 6 7 9 10 11 13 14 15 16 17 18 19 20 21 24 25 26 53 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 46 47 51 52 8 12 22 23 33 48 49 50 27 Kerosene Forced Air Heater Model PA50DKR PA75DKTR PA125DKTR PA175DKTR Filter Kit 51 52 ...

Page 10: ...e and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase Mr Heater Inc will repair or replace this product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchas...

Page 11: ...é par un fournisseur de services d entretien qualifié Cet appareil de chauffage portatif n est pas ventilé Il utilise l oxygène de l air ambiant Une circulation d air adéquate doit être assurée pour la combustion et la ventilation Voir page 3 APPAREIL DE CHAUFFAGE À AIR PULSÉ AU KÉROSÈNE GUIDE D UTILISATION ET INSTRUCTIONS DE FONCTIONNEMENT LISEZ SOIGNEUSEMENT LES INSTRUCTIONS Lisez et observez to...

Page 12: ...S OU DES PERTES MATÉRIELLES RÉSULTANT D INCENDIE D EXPLOSION DE BRÛLURE D ASPHYXIE D INTOXICATION AU MONOXYDE DE CARBONE OU D ÉLECTROCUTION SEULES LES PERSONNES APTES À COMPRENDRE ET À RESPECTER LES INSTRUCTIONS DEVRAIENT UTILISER OU EFFECTUER L ENTRETIEN DE CET APPAREIL DE CHAUFFAGE SI VOUS AVEZ BESOIN D AIDE OU D INFORMATION AU SUJET DE L APPAREIL DE CHAUFFAGE MANUEL D INSTRUCTIONS ÉTIQUETTES ET...

Page 13: ...pi du dessus et des côtés de l appareil ainsi que de la prise d air Placez l appareil à 3 m 10 pi des toiles et des revêtements plastiques et fixez les afin d empêcher tout battement 7 Attention En raison des températures élevées à la surface et à la sortie les adultes et les enfants doivent respecter les distances de sécurité pour éviter les brûlures et l inflammation des vêtements Ne touchez pas...

Page 14: ...limentation dans une prise mise à la terre de 115 V 60 Hz 1 Ø 75DKTR 125DKTR 175DKTR Réglez le thermostat au minimum et assurez vous que l interrupteur est à OFF Branchez le cordon de l appareil de chauffage dans une prise mise à la terre de 115 V 60 Hz 1 Ø Réglez le thermostat à sa position la plus élevée Démarrez l appareil de chauffage en mettant l interrupteur à ON Marche La lumière s allume à...

Page 15: ...e de la cellule au cadmium à l aide d un chiffon doux et sec 4 GICLEUR L accumulation de saleté de combustible et de carbone causée par l aube d entrée obstruera éventuellement les conduits du gicleur et entraînera une diminution du débit d air et de combustible La pression augmentera graduellement ce qui déséquilibrera le mélange air combustible et produira un surplus de fumée et d odeur Dans un ...

Page 16: ...st refroidi appuyez sur le bouton de réinitialisation et essayez de nouveau Circuit ouvert du contacteur de commande maximale 2 clignotements Verrouillage du système 1 Vérifiez le câblage vers le moteur selon le schéma de câblage du présent guide 2 Assurez vous que le bouchon du manomètre est bien en place et qu il n est pas endommagé 3 Réglez la pression pour assurer le bon fonctionnement de l ap...

Page 17: ...OIR AWG 17 VRT AWG 18 TRANSFORMATEUR D ALLUMAGE NOIR AWG 17 ÉLECTRODE RGE AWG 18 RGE AWG 18 CELLULE AU CADMIUM SCHÉMA DE LA COMMANDE DE FLAMME la position des connexions peut différer sur le circuit imprimé INTERRUPTEUR MARCHE ARRÊT NOIR AWG 18 BLC AWG 18 VRT AWG 18 MODÈLES 125KT 175KT PRISE C A ORG AWG 18 CONDENSATEUR DU MOTEUR ORG AWG 18 ROSE AWG 18 ROSE AWG 18 MOTEUR BLC AWG 18 NOIR AWG 18 CORD...

Page 18: ...831 F226831 Ensemble de rotor Rotor de pompe à air avec ailettes Raccord de nylon pour pompe à air 19 26898 26898 26898 Réceptacle 110 V 20 22104 22104 22104 Couvercle de réceptacle 21 26833 26833 26833 26833 Cylindre de pompe à air 22 21810 21810 21810 21810 Boîtier de sortie 23 21812 21812 21812 21812 Boîtier d admission 24 22257 22257 Tête de brûleur 25 F221887 F221887 F221887 F221887 Ensemble ...

Page 19: ...2 3 4 5 6 7 9 10 11 13 14 15 16 17 18 19 20 21 24 25 26 53 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 46 47 51 52 8 12 22 23 33 48 49 50 27 Appareil de chauffage à air pulsé au kérosène Modèles PA50DKR PA75DKTR PA125DKTR PA175DKTR Kit de Filtre à Carburant Filtre à carburant 51 52 ...

Page 20: ...10 Mr Heater Inc Kerosene Forced Air Heater Operating Instructions and Owner s Manual REMARQUES ...

Page 21: ...ème dans toutes vos communications avec nous GARANTIE LIMITÉE Mr Heater Inc garantit ses appareils de chauffage et ses accessoires contre les défauts de matériel et de main d œuvre pour une période de un an à partir de la date d achat Mr Heater Inc réparera ou remplacera ce produit sans frais s il est démontré qu il est devenu défectueux pendant la période de garantie et qu il est retourné à Mr He...

Page 22: ...alizarlo una agencia de servicio calificada Este es un calentador portátil a gas sin fuente propia de ventilación Utiliza el aire oxígeno del área en la cual se emplea Debe suministrarse el aire necesario para la ventilación y la combustión Ver página 3 CALENTADOR DE CALDEO A AIRE FORZADO A KEROSENE INSTRUCCIONES DE USO Y MANUAL DEL USUARIO LEA CUIDADOSAMENTE LAS INSTRUCCIONES lea y siga todas las...

Page 23: ...UAL DE INSTRUCCIO NES ETIQUETAS ETC PÓNGASE EN CONTACTO CON EL FABRICANTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACIÓN Y EXPLOSIÓN MANTENGA LOS COMBUSTIBLES SÓLIDOS TALES COMO MATERIALES DE CONSTRUCCIÓN PAPEL O CARTÓN A UNA DISTANCIA SEGURA DEL CALENTADOR COMO SE RECOMIENDA EN LAS INSTRUCCIONES NUNCA USE EL CALENTADOR EN ESPACIOS QUE CONTENGAN O PODRÍAN CONTENER COMBUSTIBLES VOLÁTILES O G...

Page 24: ... combustibles como el papel y la madera al menos a 8 pies 2 4 m de distancia de la salida del calentador y a 3 pies 1 0 m de distancia de la parte superior los costados y la entrada Colóquelo a 10 pies 3 0 m de las cubiertas de lona o plástico y asegúrelas de modo que no para que se mantengan estáticas 7 Cuidado dadas las elevadas temperaturas de la superficie y del escape tanto los adultos como l...

Page 25: ...50DKR y 75DKTR no son adecuados para usarse en pisos de madera u otros materiales combustibles Cuando lo use debe colocar el calentador sobre un material aislante adecuado de al menos 1 pulgada de espesor y que sobresalga 3 pies o más del calentador en todas las direcciones ENCENDIDO DEL CALENTADOR 1 50DKR enchufe el calentador en un tomacorriente con clavija de tierra de 115 V 60 Hz 1 Ø 75DKTR 12...

Page 26: ...pie el calentador dos veces por temporada con más frecuencia cuando hay polvo Quite el polvo acumulado del transformador quemador motor y aspas del ventilador con aire comprimido Limpie el área con un paño seco y limpio Inspeccione el área para asegurarse de quitar todos los materias extrañas especialmente alrededor del quemador y del área de combustión 3 CÉLULA DEL CAD Limpie la parte de vidrio d...

Page 27: ... SÍNTOMA RESOLUCIÓN DE PROBLEMAS Interruptor limitador máximo en circuito abierto 1 Asegúrese de que el calentador se enfríe por completo cambie el interruptor a la posición OFF espere 5 minutos e inténtelo nuevamente Chispas piden llama pero el motor no funciona o funciona lentamente 1 Verifique el cableado al motor según el esquema de cableado del manual 2 Asegúrese de que el indicador de presió...

Page 28: ... AWG BLANCO 18 AWG VERDE TOMACORRIENTE DE CA 125KT 175KT ÚNICAMENTE 18 AWG NARANJA 18 AWG NARANJA 18 AWG ROSADO 18 AWG ROSADO CONDENSADOR DEL MOTOR 18 AWG ROJO 18 AWG ROJO TRANSFORMADOR DE ENCENDIDO MOTOR 18 AWG PÚRPURA 18 AWG PÚRPURA CÉLULA DEL CAD DIAGRAMA DE CONTROL DE LA LLAMA las conexiones pueden no estar en la misma posición en la placa de circuito TIC 17 AWG NEGRO 17 AWG NEGRO ELECTRODO 18...

Page 29: ... 50DKR 75DKTR 125DKTR 175DKTR 29 21866 21866 21867 21867 Conjunto de control de la llama 30 21816 21816 21816 21816 Soporte de control de la llama 31 26920 26920 26911 26911 Sensor de llama de la célula del cad 32 21882 21868 21869 21870 Conjunto del cilindro de la cámara de combustión 33 26959 26959 26959 26959 Tapa de combustible 34 26910 26910 26910 26910 Junta de la tapa de combustible 35 2733...

Page 30: ... 9 1 2 3 4 5 6 7 9 10 11 13 14 15 16 17 18 19 20 21 24 25 26 53 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 46 47 51 52 8 12 22 23 33 48 49 50 27 Calentador de queroseno a aire forzado Modelos PA50DKR PA75DKTR PA125DKTR PA175DKTR Filtre à carburant Kit Filtre à Carburant 51 52 ...

Page 31: ...10 Mr Heater Inc Kerosene Forced Air Heater Operating Instructions and Owner s Manual NOTAS ...

Page 32: ...os contra defectos de materiales y mano de obra por un período de 1 año a partir de la fecha de compra Mr Heater Inc reparará o reemplazará este producto sin cargo si presentara desperfectos dentro del primer año tras realizada la compra siempre y cuando el cliente cubra los gastos de la devolución y presente el comprobante de compra a Mr Heater Inc dentro del período de garantía Algunos estados n...

Reviews: