The connection of Model MH35LP to an LP-Gas cylinder must 
be made in a well ventilated area using the regulator and hose 
assembly supplied with the appliance. DO NOT attempt to adjust 
this regulator. It has been preset at the factory to provide safe and 
proper operation of the appliance. Use a 7/8” open end wrench 
to connect the POL fitting (supplied with the LP regulator) to the 
LP-Gas cylinder. Turn the POL nut in a counter-clockwise direction 
(left hand thread) until tight. DO NOT use pipe compound on POL 
threads.

The heater must be located at least six feet away from any LP-Gas 
cylinder and must not be directed toward any LP-Gas cylinder 
within 20 feet. If more than one heater is used, they and the 
supply cylinders must be separated by at least 20 feet.

The gas supply must be turned off at the LP-Gas supply cylinder 
when the heater is not in use.

When the heater is to be stored indoors, the connection between 
the LP-Gas supply cylinder and the heater must be disconnected 
and the cylinder removed from the heater and stored in 
accordance with chapter 5 of the Standard for the Storage and 
Handling of Liquefied Petroleum Gases, ANSI/NF-PA 58 (U.S.), OR 
CAN/CGA B149.2 (Canada).

If connected to a permanently installed LP Gas supply system, the 
system requires the use of a two-stage gas regulator assembly 
which is normally provided by your LP-Gas dealer as part of the 
LP-Gas supply system. Consult with your local LP-Gas dealer for 
details concerning proper equipment and installation.

Piping must be clean and free from scale or burr.

Before attempting to ignite the appliance, all gas fittings and 
connections must be thoroughly checked for gas leaks. Apply a 
small amount of a mild soap and water solution to all fittings and 
connections and observe for escaping bubbles. If any leaks are 
detected, shut off the gas supply to the appliance immediately. 
Wait a minimum of five minutes, repair the leak(s) and retest for 
leakage. Dry all fittings and connections after leak testing.

WARNING 

NEVER USE A fLAmE fOR GAS LEAK TESTING.

OPERATING INSTRUCTIONS

WARNING: 

If YOU DO NOT fOLLOW 

THESE INSTRUcTION EXAcTLY, A fIRE 
OR EXPLOSION mAY RESULT cAUSING 
PROPERTY DAmAGE, PERSONAL INJURY, 
OR LOSS Of LIfE.

 

CAUTION

THIS APPLIANcE IS HOT DURING 

NORmAL OPERATION. AVOID 

PHYSIcAL cONTAcT.

CAUTION

DO NOT PLAcE cLOTHING OR 

OTHER cOmBUSTIBLE mATERIALS 
ON THIS APPLIANcE.

dO nOt operate this heater if any part has been under 
water. call a qualified service technician to inspect the 
appliance and to 

replace any part of the control system or gas 

control valve which has been under water.

This appliance must be installed and operated only in locations 
where the potential for physical damage to the appliance is 
reduced to a minimum. The owner/operator of this appliance 
must ensure that precautions are taken to protect the appliance 
from physical damage.

LIGHTING AND SHUT-DOWN
lighting the Heater:

1.  Before attempting to light the heater, smell all around 

the heater area for gas. Be sure to smell next to the floor 
because LP-Gas is heavier than air and will settle on the 
floor. Turn on the gas supply to the appliance and check 
all fittings and connections for gas leaks using a mild 
soap and water solution. NEVER use a match to check 
for gas leaks. Should a gas leak occur, shut off the gas 
supply to the appliance immediately. Wait a minimum of 
five minutes before repairing the leak.

2.  Use only the fuel intended for this appliance. Check the 

appliance rating plate for the correct fuel information.

3.  Turn off the main gas supply to the appliance. Wait five 

minutes.

4.  Turn on the main gas supply.

5.  Depress red spark ignition button repeatedly or with 

a lighted match held to the burner face, depress and 
hold the reset button on the safety valve. After the 
burner ignites, hold the reset button depressed for 
about one minute or until the burner stays lit when 
the reset button is released. 

dO nOt light the gas 

at the burner orifice. dO nOt face heater when 
attempting to light. always stand to the side of the 
unit when lighting

.

NOTE: In cases where long runs of gas supply lines have been 
installed ahead of the appliance, it may be necessary to bleed 
trapped air out of the supply lines before lighting the burner. 
New installations generally require bleeding of supply lines. 
Wait a minimum of five minutes after bleeding the supply 
lines before attempting to light the heater.

6. 

iMpOrtant: dO nOt attempt to adjust the main 
burner input using the main gas supply valve

, for this 

may cause the thermocouple to shut down the burner.

e5

Operating Instructions and Owner’s Manual

Gas-Fired Infra-Red Portable Construction Heater

Summary of Contents for MH35LP

Page 1: ...MATION SUCH AS INSTRUCTION MANUALS LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DI...

Page 2: ...ONLY IN A WELL VENTILATED AREA The flow of combustion and ventilation air must not be obstructed DO NOT use in a tightly enclosed area Any combustion process requires and consumes oxygen and may prod...

Page 3: ...heater nameplate INSTALLATION INSTRUCTIONS GENERAL For the U S and or Canada the installation of this appliance must comply with local and or Provincial codes or in the absence of these codes With th...

Page 4: ...pliance produces radiant heat Therefore it must be located at least six feet away from any LP Gas container and must not be directed toward any LP Gas container within 20 feet The heater must be insta...

Page 5: ...HIS APPLIANCE IS HOT DURING NORMAL OPERATION AVOID PHYSICAL CONTACT CAUTION DO NOT PLACE CLOTHING OR OTHER COMBUSTIBLE MATERIALS ON THIS APPLIANCE DO NOT operate this heater if any part has been under...

Page 6: ...ng a damp cloth DO NOT clean the heater by spraying water on it Wipe the outside of the heater off with a dry cloth after cleaning Clean the inside of the heater using compressed air Blow air back and...

Page 7: ...ll carry a one 1 year warranty on the applicable warranties of the suppliers The sole responsibility of MR HEATER under this warranty shall be to replace or repair any part for which a written claim i...

Page 8: ...UES ET D EXPLOSION TEL QUE MENTIONN DANS LE MANUEL DE L UTILISATEUR VEUILLEZ GARDER LES COMBUSTIBLES SOLIDES TELS QUE LES MAT RIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON DISTANCE DE L APPAREIL DE CHA...

Page 9: ...STIONS QUANT AUX DIFF RENTES UTILISATIONS POSSIBLES VEUILLEZ COMMUNIQUER AVEC VOTRE SERVICE DES INCENDIES LOCAL Pour certaines applications d autres normes r gissent l utilisation de gaz combustibles...

Page 10: ...l air il peut y avoir plus d odeurs des niveaux inf rieurs Soyez toujours tre en alerte pour l odeur de gaz la plus insignifiante Si vous continuez d tecter n importe quelle odeur de gaz aussi faible...

Page 11: ...ISEZ JAMAIS l appareil de chauffage avec la bonbonne de gaz en une position autre que verticale EMPLACEMENT M me si l appareil de chauffage est muni d un interrupteur de bascule la bonbonne de gaz et...

Page 12: ...UT S ENSUIVRE ET CAUSER DES DOMMAGES DE BIENS DES BLESSURES CORPORELLES OU LA MORT AVERTISSEMENT LE PR SENT APPAREIL DEVIENT TR S CHAUD EN COURS D UTILISATION VITEZ TOUT CONTACT PHYSIQUE AVERTISSEMENT...

Page 13: ...nez l appareil et attendez qu il soit enti rement refroidi attendre au moins 20 minutes avant de le nettoyer Nettoyez l ext rieur de l appareil l aide d un chiffon humide NE NETTOYEZ PAS l appareil de...

Page 14: ...quelle pi ce pour laquelle une r clamation crite est faite MR HEATER dans la limite de validit de cette garantie qui est retourn e sur demande MR HEATER FOB Cleveland Ohio ou FOB n importe quel centre...

Page 15: ...R COMO MANUALES DE INSTRUCCIONES ETIQUETAS ETC P NGASE EN CONTACTO CON EL FABRICANTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N MANTENGA LOS COMBUSTIBLES S LIDOS COMO MATERIALES...

Page 16: ...eso de combusti n requiere y consume ox geno y puede producir mon xido de carbono Este calentador debe usarse con la ventilaci n adecuada Debe haber dos aberturas directamente hacia el exterior una ba...

Page 17: ...odujera una fuga de gas usted debe poder oler el gas combustible Dado que el propano LP es m s pesado que el aire debe tratar de detectar el olor lo m s cerca del piso posible CUALQUIER OLOR A GAS SER...

Page 18: ...LP y no debe apuntar hacia ning n contenedor de gas LP a menos de 6 metros El calentador debe instalarse en un lugar en el que no quede expuesto directamente a las salpicaduras de agua lluvia o goteo...

Page 19: ...O COLOQUE ROPA U OTRO MATERIAL COMBUSTIBLE SOBRE ESTE ARTEFACTO NO use este calentador si alguna de las piezas ha estado bajo el agua Cont ctese de inmediato con un t cnico de mantenimiento calificado...

Page 20: ...r con aire comprimido Limpie todo el quemador con aire hasta que haya quitado toda la suciedad de la superficie del reverberador y la rejilla Limpie el Venturi desde el extremo de control del calentad...

Page 21: ...rados por MR HEATER tendr n un 1 a o de garant a sobre las garant as correspondientes de los proveedores La nica responsabilidad de MR HEATER en virtud de esta garant a ser la de reemplazar o reparar...