background image

11

Installation Instructions and Owner’s Manual

Unvented Natural Gas Vent Free Room Heaters

THERMOSTAT CONTROL OPERATION

FOR IR20NGT / IR30NGT:

 The thermostatic control 

used simply turns on and off the burner. 

FOR BF20NGT / BF30NGT: 

The thermostatic control 

used modulates the flame size as the temperature gets 

closer to set point, then it turns off the burner upon 

reaching temperature.
The burner will cycle back on when room temperature 

drops below the set temperature. The control knob can 

be set to any heat level between 1 and 5. Selecting the 

HI setting will cause the burner to remain on.

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF HEATER

1.  Turn control knob clockwise to the OFF posi-

tion.

2.  Turn off all electrical power to the appliance if 

servicing is to be preformed.

3.  Turn off equipment shutoff valve.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1.  Turn control knob clockwise to the PILOT/IGN 

position.

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern 

often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure 

22 shows an incorrect pilot flame pattern. The incorrect 

pilot flame pattern is not touching thermocouple. This 

will cause the thermocouple to cool. When the thermo-

couple cools, the heater will shut down. If pilot flame 

pattern is incorrect, as shown in Figure 22:

• 

Turn heater off (see 

To Turn OFF Gas to Appli-

ance

, above.

 

• 

See Troubleshooting, pages 14-15.

CLEANING AND MAINTENANCE

WARNING:

 Turn off heater and let cool before 

servicing. 

CAUTION:

 You must keep control areas, burner 

and circulation air passageways of heater clean. 

Inspect these areas of heater before use. Have 

the heater inspected yearly by a qualified service 

person. Heater may need more frequent cleaning 

due to excess lent from carpeting, bedding material, 

pet hair, etc. 
Make sure grille guard is in place before running 

heater. If screen or grille guard is removed for 

servicing it must be replaced prior to operating the 

heater. 

technician to inspect the appliance and to re-

place any part of the control system which has 

been underwater.

LIGHTING INSTRUCTIONS

1.  STOP! Read the all safety information included 

with and on the side of heater.

2.  Make sure the equipment shutoff valve is fully 

open.

3.  Push in gas control knob and slightly turn clock-

wise to the OFF position (see figure 19).

4.  Wait five (5) minutes. Then smell for gas includ-

ing near the floor. If you smell gas, STOP! Fol-

low “B” in the safety information above. If you 

do not smell gas, go to the next step.

5.  Push in and turn control knob counterclockwise 

to PILOT. Press in control knob for five (5) sec-

onds.

Note:

 The first time that the heater is operated after 

connecting the gas supply, the control knob should 

be depressed for about 30 seconds. This will allow 

air to bleed from the gas system. This may take 

longer in some installations

 Figure 19.

6.  With control knob pressed in, push down and 

release the ignition button. This will light pilot. If 

needed keep pressing igniter button until pilot 

lights.

7.  Keep control knob pressed in for (30) seconds 

after lighting pilot. After 30 seconds, release 

control knob. 

• 

If pilot does not stay lit, refer to Troubleshoot-

ing, pages 14 & 15. Also, contact a qualified 

service person of gas supplier for repairs. 

• 

If control knob does not pop up when released, 

contact a qualified service person or gas sup-

plier for repairs.

8.

 

  When the pilot is lit, turn control knob coun-

terclockwise to heating level. The main burner 

should light.

9.  To select the desired heat level, turn the 

temperature setting knob counterclockwise to 

between 1 & 5. 

Ignitor Button

Control Knob

Summary of Contents for 000 BTU Blue Flame Heaters

Page 1: ...om the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Fresh Air for Combustion and Ventilation section on page 4 of this manual WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additi...

Page 2: ...mable material on or near the appliance Never place any objects on the heater Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Surface of heater becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Heater will remain hot for a time after shutdown Allow heater surfaces to cool before han...

Page 3: ...Keep all air openings in heater clear free of debris or any blockage This will insure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater 6 Do not r...

Page 4: ...g are excerpts from National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Com bustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space This heater must not be installed in a confined space or unusually tight construction unless provisions are pro vided for adequate combus...

Page 5: ... hr Vent Free Heater 20 000 Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide a...

Page 6: ... sible provide greater clearances from the floor ceil ing and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all ap pliance in both spaces Ventilation from Outdoors If necessary provide extra fresh air by using ventila tion grills or ducts Connect these items directly to the outdoors or spaces open t...

Page 7: ...er will be located Make sure mounting bracket is level For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the floor and joining wall 2 Mark screw locations on wall see figure 7 3 Remove tape and mount bracket from wall Figure 7 Attaching to Wall Stud For attaching mounting b...

Page 8: ...ing bottom mounting screw into wall stud drill holes at marked locations using 9 64 drill bit 5 Re place heater onto mounting bracket 6 Place spacers between bottom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 8 Tighte...

Page 9: ...abinet Ground Joint Union Equipment Shutoff Valve From Gas Meter 4 W C to 10 5 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap Test Gauge Connection Reducer Bushing to 1 8 NPT 3 Minimum taminants This keeps them from going into heater If sediment trap is not installed or is installed improperly heater may not run correctly IMPORTANT Hold pressure...

Page 10: ...your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been underwater Immediately call a qualified service Pressur...

Page 11: ...n Heater may need more frequent cleaning due to excess lent from carpeting bedding material pet hair etc Make sure grille guard is in place before running heater If screen or grille guard is removed for servicing it must be replaced prior to operating the heater technician to inspect the appliance and to re place any part of the control system which has been underwater LIGHTING INSTRUCTIONS 1 STOP...

Page 12: ...vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit ever 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a...

Page 13: ...13 Installation Instructions and Owner s Manual Unvented Natural Gas Vent Free Room Heaters This page intentionally left blank ...

Page 14: ...gas regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple damaged 5 Control valve damaged 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds...

Page 15: ... ances see Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni ture 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater prod...

Page 16: ...hrough Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase Mr Heater Inc will repair or replace this product free of charge if it has been proven to be defective within the 1 year per...