DAW-500S WELDER/A.C. GENERATOR — PARTS & OPERATION MANUAL — REV.#0 (07/19/01) — PAGE 31
7. When the engine starts, the
oil pressure
light and
charge
light should go out. If these lights stay on, immediately
stop the engine and check the system and wiring (refer to
the
Kubota Engine Operator's Manual
).
8. Let the engine idle for five minutes with the
automatic idle
control switch
in the “ON” position.
9. Check the engine for abnormal vibrations, noises and oil
leakage.
10. Check the generator's output voltage by referring to the
DC voltmeter on the control panel.
Shutdown
1. Remove the load from the welder/AC generator, then
place both the main and GFCI circuit breakers to the
"OFF" position.
2. Listen for the engine speed to drop. Run at low speed
for 3-5 minutes.
3. Stop the engine by turning the key to “
STOP
” position
and remove the key. Turn the fuel cock lever to the
“OFF” position.
DAW-500S — ENGINE OPERATING INSTRUCTIONS