PAGE 14 —DAW-500S WELDER/A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #0 (07/19/01)
DAW-500S — CONTROLS AND INDICATORS
15. Fuel Drain Plug –
Remove this plug to drain fuel from the
fuel tank.
16. Frame Ground Lug –
Connect a ground strap between
this lug and a ground rod. Make sure the ground rod is
inserted deep into the ground to provide a good earth
ground. Consult with local Electrical and Safety Codes for
proper connection.
17. Oil Filter –
Provides oil filtering for the engine.
18. Ignition Switch –
With key inserted turn clockwise to start
engine.
19. Hour Meter –
Indicates number of hours machine has
been in use or hours engine was run.
20. Circuit Protector Circuit Breaker –
This single pole circuit
breaker provides circuit protection (120V @20 amps) for
the G.F.C.I. receptacle.
21. Receptacle G.F.C.I. –
This receptacle provides 120 volts
output at 20 amps.
22. Receptacle –
Provides 120 volts output at 25 amps.
23. Welding Output Terminals –
Connect the welding cable
to this terminal. Select the appropriate polarities according
to the application. See Table 7.
!
Low Oil Pressure
!
High Water Temperature
!
Electrical System Is Not Charging Properly
!
Preheat Indicator
27. Sub-Selector Switch-
This switch is used to select type of
welding and welding voltage needed. This switch will not
work in CC mode.
28. DC Voltmeter-
Indicated the amount of voltage used during
welding in CV mode.
29. DC Ammeter-
Indicates the amount of amperage being
used during welding in CC mode.
30. Idle Control Switch –
Regulates the engine speed when
the welder/AC generator is under load.
31. Warning Lamp Display –
Lights red when the following
conditions occur:
Figure 3. Controls and Indicators (con't)
24. Main Circuit Breaker –
This single-pole circuit breaker
provides circuit protection (125V @25 amps) for the electric
parts assembly.
25. Current Control (CC) Voltage Control (CV) Adjustment
Knobs –
Use these controls to adjust welding current and
voltage.
26. Welding Type (Wire/Stick) Selector Switch (CV/CC) –
Turn this selector switch to either the CV or CC for welding.
DO NOT
turn this switch under load.