PAGE 28 — DCA45SSIU4F 60 HZ GENERATOR • OPERATION MANUAL — REV. #5 (02/28/20)
3.
NEVER overfill the fuel tank
— It is important to read
the fuel gauge when filling the trailer fuel tank.
DO NOT
wait for fuel to rise in the filler neck (Figure 32).
Figure 32. Full Fuel Tank
Figure 33. Fuel Expansion
COOLANT
(ANTIFREEZE/SUMMER COOLANT/WATER)
Isuzu
recommends antifreeze/summer coolant for use in their
engines, which can be purchased in concentrate (and mixed
with 50% demineralized water) or pre-diluted. See the
Isuzu
Engine Owner’s Manual
for further details.
Day-to-day addition of coolant is done from the recovery
tank. When adding coolant to the radiator,
DO NOT
remove
the radiator cap until the unit has completely cooled. See
Table 12 for engine, radiator, and recovery tank coolant
capacities.
FUEL
LEVEL
FUEL GAUGE LOCATED
ON CONTROL PANEL
CAUTION
DO NOT OVERFILL
the fuel system. Leave room for
fuel expansion. Fuel expands when heated (Figure 33).
Heat Source
!
!
Fuel EXPANDS
When Heated!
WARNING
If adding coolant/antifreeze mix to the
radiator,
DO NOT
remove the radiator cap
until the unit has completely cooled. The
possibility of
hot!
coolant exists which can
cause severe burns.
1. Verify that the coolant level in the coolant recovery tank
is between the
FULL
and
LOW
markings as shown in
Figure 34.
Figure 34. Coolant Recovery Tank
Operation in Freezing Weather
When operating in freezing weather, be certain the proper
amount of antifreeze (Table 13) has been added.
NOTICE
Normally, only the coolant level in the recovery tank
needs to be checked. However, the radiator cap should
be opened once a week to verify that coolant is visible
(full) inside the radiator.
Table 12. Coolant Capacity
Engine and Radiator
4.44 gal. (16.8 liters)
Reserve Tank
0.29 gal (1.1 liters)
Table 13. Antifreeze
Operating Temperatures
Vol %
Antifreeze
Freezing Point
°C
°F
50
–37
–34
NOTICE
When the antifreeze is mixed with water, the antifreeze
mixing ratio
must be
less than 50%.
INSPECTION/SETUP
Summary of Contents for WHISPERWATT DCA45SSIU4F
Page 2: ...PAGE 2 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PROPOSITION 65 WARNING ...
Page 52: ...PAGE 52 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 CONTROLLER WIRING DIAGRAM ...
Page 53: ...DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PAGE 53 NOTES ...