PAGE 38 — DCA45SSIU4F 60 HZ GENERATOR • OPERATION MANUAL — REV. #5 (02/28/20)
MAINTENANCE
ELECTROMAGNETIC FUEL PUMP (500 HOURS)
The filter inside the fuel pump (Figure 58) is either a paper
type or steel mesh type depending on the fuel pump type.
Clean or replace the fuel pump filter as follows:
1. Disconnect any electrical connections that are attached
to the fuel pump.
2. Prepare a fuel collector to drain the fuel into. Secure
any fuel lines to prevent fuel from spilling.
3. Remove the fuel pump from the generator enclosure.
4. Remove the filter and gasket from the fuel pump
housing.
.
Figure 58. Electromagnetic Fuel Pump
5. Clean or replace the fuel pump filter. Replace both
gaskets.
6. Reassemble the fuel pump and mount it back onto the
generator enclosure.
7. Reconnect all fuel lines and electrical components.
8. Check for fuel leaks.
GASKET
GASKET
COVER
FILTER
ELECTRO-
MAGNETIC
FUEL PUMP
NOTICE
When the fuel pump filter is removed, always make sure
to replace both gaskets and clean the magnet portion
inside the cover.
DRAINING THE CONTAINMENT TANK
1. This generator is equipped with an environmental
containment tank. Inspect this tank regularly.
2. If the tank becomes full with fluids, remove the drain
bolt (Figure 59), then allow the fluids to drain into a
suitable container.
Figure 59. Draining Containment Tank
45
CONTAINMENT
DRAIN BOLT
Summary of Contents for WHISPERWATT DCA45SSIU4F
Page 2: ...PAGE 2 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PROPOSITION 65 WARNING ...
Page 52: ...PAGE 52 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 CONTROLLER WIRING DIAGRAM ...
Page 53: ...DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PAGE 53 NOTES ...