background image

Dear users:

Thank you for choosing our products!

Safety Instructions

1. Since the applicable voltage of the controller exceeds the safety limit of human body, 
please read the manual carefully before operation and operate this controller after the  
safety operation training is completed.
2. Since no part is required to be maintained or repaired inside the controller, please do  
not disassemble and repair the controller by yourself.

3. Please install the controller indoors to avoid exposure of components and keep water  
away from the controller.
4. Since the cooling fin will be very hot during operation, please install the controller in a 
well-ventilated place.
5. Suitable fuse or circuit breaker is recommended to be equipped outside the controller.
6. Before installing and adjusting the wiring of the controller, make sure to disconnect the 
wiring of the photovoltaic array and the fuse or circuit breaker near the accumulator battery 
terminals.

7. After installation, check whether all wiring is tightly connected to avoid the danger of  
heat accumulation due to loose connection.

Warning: Indicates that this operation is dangerous and safety preparations must be made 
before operation.

Attention: Indicates destructive operation.

Tips: Indicates suggestions and tips to the operator.

!

Contents

01

02

03
03

04
04
04

1. Product introduction

1.1 Product overview
1.2 Product features
1.3 Description on appearance and interface

07

12

11

12

12

12

13

8.1 Battery parameter list
8.2 Parameter setting list
8.3 Type of battery
8.4.Equalizing charging\boost charging\floating charging\charging reconnect voltage

\

over

8.5 System voltage
8.6 Charge current
8.7 Full-charging setting
8.8 Constant voltage output of lead acid battery 
8.9 Light control voltage
8.10 Light control delay
8.11 Load mode
8.12 Load short-circuit protection switch
8.13 Over-discharge delay 
8.14 Temperature unit
8.15 RS485 communication baud rate
8.16 Equipment address
8.17 System restart
8.18 Factory reset
8.19 Historical data cleaning

07

4.1 Charging of lead-acid battery

06
07

2. Introduction to maximum power tracking technology
3. Technical parameters
4. Charging

08
08
09

      4.2 Charging of lithium battery

5. Battery Temperature Sampling and Control
6. Load output

7. Menu

09

7.1 View menu

10

8. Parameter setting

10

13
13
13
13
14
14
14
15
15
15
15
15
16
16
16
17
18
18

9. TTL communication

10. RS485&CAN communication(Optional

)

11. Key
12. System alarms
13. Common problems and solutions
14. Installation

18

14.1 Installation precautions

19

14.2 Installation steps

20
20
21

15. Protection 
16. System maintenance
17. Product dimensions
18. System connection diagram

22
22

18.1 System wiring diagram

!

-discharge reconnect voltage\over-discharge voltage

12

Summary of Contents for Shiner2410

Page 1: ...Version V1 01 MPPT Solar Charge Controller Subject to change without notice User Manual Code 106998 ...

Page 2: ...d tips to the operator Contents 01 02 03 03 04 04 04 1 Product introduction 1 1 Product overview 1 2 Product features 1 3 Description on appearance and interface 07 12 11 12 12 12 13 8 1 Battery parameter list 8 2 Parameter setting list 8 3 Type of battery 8 4 Equalizing charging boost charging floating charging charging reconnect voltage over 8 5 System voltage 8 6 Charge current 8 7 Full charging...

Page 3: ...attery voltage is about 12V therefore when the common charge controller is charging the battery the voltage of the solar battery is about 12V that is the solar battery does not fully exert its 1 2 Product features S N Name 1 LCD 2 Button 3 Solar panel positive interface 4 Solar panel negative interface 5 Battery negative interface 6 Load negative interface 7 S N Name Battery positive interface Loa...

Page 4: ...Static power consumption 10mA Battery Type SLD GEL FLD LI USE USELI SLD as default System voltage 12V 24V Battery operating voltage range 8V 32V Rated charging current 10A 20A Maximum solar panel power 130W 12V 260W 24V 260W 12V 520W 24V Maximum PV open circuit voltage 60V 55V protection 50V recovery MPPT operating voltage range Battery voltage 2V 45V MPPT tracking efficiency 99 Charging conversion...

Page 5: ... full charging When the battery voltage is as low as the reconnect voltage of boost charging the system will exit the floating charging stage and re enter the next charging cycle 07 08 Fig 4 1 Charging curve of lead acid battery Charging voltage Time Equalizing charging voltage MPPT Boost charging voltage Floating charging voltage Charging reconnect voltage Constant voltage Floating Charging curren...

Page 6: ...age 14 4V 14 2V 14 6V 14 4V 9 17V 9 17V Float charge voltage 13 8V 13 8V 13 8V 9 17V Boost charging reconnect voltage 13 2V 13 2V 13 2V 13 2V 9 17V 9 17V Over discharge restoring voltage 12 6V 12 6V 12 6V 12 6V 9 17V 9 17V Under voltage alarming voltage 12 0V 12 0V 12 0V 12 0V 9 17V 9 17V Over discharge voltage 11 1V 11 1V 11 1V 11 1V 9 17V 9 17V Over discharge cutoff voltage 10 6V 10 6V 10 6V 10 ...

Page 7: ...0 115200kps 9600kps Device address 1 247 1 System restart F01 Function key Factory data reset F02 Function key Clear historical data F03 Function key Note 24V battery system automatically multiply by 2 according to the set value to get the actual control value Boost charging voltage Float charge voltage Light control voltage 8 3 Type of battery Please refer to 8 1 and 8 2 for setting 8 4 Equalizin...

Page 8: ... light control When the solar panel voltage is less than the Light control ON voltage with a duration is more than the light control delay turn on the load When the solar panel voltage is greater than the light control OFF voltage with a duration is greater than the light control delay turn off the load 1 14 Light control time control 1 14 h After the duration during which the solar panel voltage i...

Page 9: ...ion line sequence definition 10 RS485 CAN communication Optional 8 15 RS485 communication baud rate 8 16 Equipment address The device communication address can be modified according to actual needs The RS485 communication baud rate can be modified according to actual needs 8 17 System restart Single press ENTER F01 flashes single press ENTER again the controller will reboot Definition S N Positive term...

Page 10: ...ery may produce combustible gas Stay away from sparks When installing outdoors avoid direct sunlight and rain seeping The falsely connected connection points and corroded wires may cause great heat melt the wire insulation burn the surrounding materials and even cause fire Therefore it is necessary to ensure that all connectors are tightened and the wires are preferably fixed with ties to avoid shak...

Page 11: ...r or replace timely if any Check whether there is any exposed or broken wire or wire with poor insulation and repair or replace timely if any Check whether there is dirt nesting insects or corrosion and clean timely if any Warning There is a risk of electrical shock Before carrying out checks or operations above make sure that all power supplies for the controller are disconnected Any non professi...

Page 12: ... spacing 137 77mm Fixed hole position φ4 5mm 18 System wiring diagram 18 1 System wiring diagram 22 17 Product Dimensions 17 1 Shiner2410 17 2 Shiner2420 Model Shiner2420 Product dimension 181 118 61 7mm Mounting hole spacing 161 96mm Fixed hole position φ4 5mm fuses ...

Reviews: