3.5.2.20 PC/104-
PLUS
Interface Connector (J53)
For more detailed information please refer to the PC/104-PLUS Specification, Rev. 2.2.
Number
Row A
Row B
Row C
Row D
Pin Assignment
1
GND
NC
+5 V
AD0
2
V
IO
*3
AD2
AD1
+5 V
3
AD5
GND
AD4
AD3
4
C/BE0
AD7
GND
AD6
5
GND
AD9
AD8
GND (M66EN)
*2
6
AD11
V
IO
*3
AD10
GND
7
AD14
AD13
GND
AD12
8
+3.3 V
C/BE1
AD15
+3.3 V
9
SERR
GND
Not Connected PAR
10
GND
PERR
+3.3 V
Not Connected
11
STOP
+3.3 V
LOCK
GND
12
+3.3 V
TRDY
GND
DEVSEL
13
FRAME
GND
IRDY
+3.3 V
14
GND
AD16
+3.3 V
C/BE2
15
AD18
+3.3 V
AD17
GND
16
AD21
AD20
GND
AD19
17
+3.3 V
AD23
AD22
+3.3 V
18
IDSEL0
GND
IDSEL1
IDSEL2
19
AD24
C/BE3
V
IO
*3
IDSEL3
20
GND
AD26
AD25
GND
21
AD29
+5 V
AD28
AD27
22
+5 V
AD30
GND
AD31
23
REQ0
GND
REQ1
V
IO
*3
24
GND
REQ2
+5 V
GNT0
25
GNT1
V
IO
*3
GNT2
GND
26
+5 V
CLK0
GND
CLK1
27
CLK2
+5 V
CLK3
GND
28
GND
INTD
+5 V
RST
29
(+12 V)
*1
INTA
INTB
INTC
30
(-12 V)
*1
REQ3
GNT3
GND
ABCD
1
30
Figure 47:
PC/104+ Connector
(Samtec, ESQT-130-03-MQ-368)
Notes:
*1
:
-
12 V and 12 V are only available if supplied to the Internal Power Connector 1 (J4) from a power supply (please refer to
*2
:
The PC/104-
PLUS
interface works with 33MHz bus clock.
*3
:
The PC/104-
PLUS
IO-voltage can be set to +3.3 V or to +5.0 V with the DIP Switch 3 (please refer to chapter 3.4.3).
For the maximum allowed current on each voltage please refer to chapter 3.7.
3.5.2.21 SMB Connector (J48)
This connector is reserved for MPL system expansions.
Pin
Signal
Description
Pin Assignment
1
+5 V
+5 V system voltage
2
+5 V STBY
+5 V standby system voltage
3
+3.3 V
+3.3 V system voltage
4
SMB_CLK
System Management Bus clock
5
SMB_DATA
System Management Bus data
6
SMB_ALERT
System Management Bus alert
7
PWRBTn
ATX Power Button (since PCB rev. C)
8
SLP_S4
ATX S4 Sleep Control
9
GND
Ground
10
GND
Ground
2
10
1
9
Figure 48:
SM Bus Connector (Samtec, EHT-
105-01-S-D-SMLC)
3.5.2.22 IPT700 Connector (J14)
This connector is reserved for MPL test purpose.
3.5.2.23 JTAG Port Connector (J50)
This connector is reserved for MPL production purpose.
3.5.2.24 LPC Bus Expansion Connector (J42)
This connector is reserved for future MPL system expansions.
2012 by MPL AG
41
MEH-10126-201 Rev. F
High-Tech • Made in Switzerland
PIP19 / PIP20 / PIP22 / PIP23
Technical Reference Manual